199
KPM.X.Systemhandbuch_X3.0.EN.V1.9 | Subject to misprints and technical changes.
•
The door exit button is used to open automatic doors or separation systems. Each
operation of the door exit button is recorded in the event protocol.
•
Door status monitoring enables the query of the door contact status (open or
closed). If the door contact is connected in series with a latch contact, then the door
status "closed and locked" can be monitored.
Figure 245
–
Door status monitoring event log
The event log and system log document the various functions:
Figure 246
–
Online wall reader event log
Note:
The Xesar 3.0 functionalities of the online wall reader are not available in X2.2
(e.g., online configuration, timed online configuration, door contact). Only the
door button can also be used in X2.2, but the event is not displayed in the X2.2
software.