27
KPM.X.Systemhandbuch_X3.0.EN.V1.9 | 05/2019 | Subjects to misprints and technical changes.
Visual and audible signalling
Xesar wall readers indicate events visually and audibly. For this purpose, there is an LED at the top
edge of the Xesar wall reader. For a list of all available signals please refer to section:
access components signal events
Reader area, ON/OFF status light
The reader unit sensor is located behind the glass panel of the Xesar wall reader between the EVVA
logo and the LED. The status light of the Xesar wall reader lights up continuously during on-going
operation to facilitate localising the reader unit in dark environments.
Functional principle
Hold an identification medium to the reader unit and the Xesar control unit (connected to the Xesar
wall reader) checks the identification medium. The authorisation is switched according to the
jumper settings and the respectively addressed relay of the Xesar control unit and the configuration.
(See cover plan in the Xesar control unit ->
JP2
)
.
Xesar
control
units
feature
an
event
memory
for
the
last
1,000
events. Once the event memory is full, the system overwrites the oldest entries with the most
recent events. For this reason, it is important to regularly synchronise events to prevent event
records from being lost.
2.1.4.2
Xesar wall reader connection print
Use the connection label to connect Xesar wall readers to the connecting cables of the Xesar
control unit. Please note the data and information in the assembly manual enclosed with
your Xesar product; in particular the jumper position of the JP1 jumper to prevent malfunc-
tions.
Figure 13: Xesar wall reader connection print (sample image)
We have provided the assembly manual and the data sheet of the corresponding Xesar product on
our homepage:
https://www.evva.com/uk-en/products/electroniclockingsystemsaccesscontrolsys-
Important notes on use, general legal information, danger to life and limb,
risk of explosion, climatic and environmental effects, installation instruc-
tions and use of batteries; please refer to our safety instructions on opera-
tion and cleaning which are included and can be found on our website at:
https://www.evva.com/uk-en/products/electroniclockingsystemsaccesscontrolsys-
tems/xesar/