31
KPM.X.Systemhandbuch_X3.0.EN.V1.9 | 05/2019 | Subjects to misprints and technical changes.
2.3
Xesar access components signal events
Signal
number
Event
Visual
signal
Audible signal
Note
Signal 1
Unlocking
attempt
with authorised me-
dium
⚫⚫⚫⚫⚫
mmmmm
General: If several
cards are in use, the
signal is only output af-
ter the last card is read
(yes, no or no EVVA
card)
Signal 2
End of release
⚫⚫⚫⚫⚫
ttttt
Signal 3
Rejected
medium
⚫⚫
-
⚫⚫
-
⚫⚫
-
⚫⚫
hh-hh-hh-hh
Signal 4
Unlocking
attempt
with authorised me-
dium and activated Of-
fice Mode
⚫⚫⚫⚫
--
⚫⚫⚫⚫
tttt
—
hhhh
Signal 5
Start of Office Mode
⚫⚫⚫⚫
--
⚫⚫⚫⚫
tttt
—
hhhh
Signal 6
End of Office Mode
⚫⚫⚫⚫
--
⚫⚫⚫⚫
hhhh
—
tttt
Signal 7
Opening attempt with
authorised
medium,
signal
indicates
drained battery
⚫⚫
--
⚫⚫
--
⚫⚫
--
⚫⚫
h----h----h----h----
Signal 8
Battery inserted or
component reboot
⚫⚫
--
⚫⚫
--
⚫⚫
tt
—
mm
—
hh
After having inserted
batteries,
battery
charge status display
possible
Signal 9
Medium without EVVA
segmentation;
me-
dium faulty, other sys-
tem
No signals
Signal 10 Hardware faulty
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
⚫
-
--
mmm---mmm--
-mmm---mmm-
--mmm---
mmm---mmm--
-mmm---mmm-
--mmm---
Signal 11
Communication
process with PPD
(Xesar)
⚫
-
⚫
-
⚫
-
⚫
-
⚫
-
⚫
Signal 12
Communication
successful
⚫⚫⚫⚫⚫
hhhhh