E-80-136KTL User Manual
Copyright ©EVOLVE ENERGY GROUP CO.,LTD
- 34 -
measures to avoid the snow and rain enter wiring box. Otherwise, should not
open the wiring box.
⚫
Please do not unused screw in the wiring box.
Step 1:
Use M6 driver to unscrew the two screws on the wiring box.
Step 2
:
Open wiring box cover
Figure 5-5 Open wiring box
5.4.2 Wiring Terminal and Precautions
Note
:
⚫
Before connecting to grid, please ensure the grid voltage and frequency of local
grid meet the requirement of inverter, any question please seek local grid
company for help.
⚫
Inverter can only connect to grid after getting the permission from local grid
company
⚫
Should not connect any loads between inverter and AC circuit breaker
⚫
OT/DT Requirement
:
⚫
When use copper core cable, please use copper terminal connector
⚫
When use copper clad aluminum cable, please use copper terminal connector
⚫
When use aluminum core cable, please use Copper and aluminum transition
terminal connector or aluminum terminal connector