background image

规 格 说明

 

 

Ew-282

Parameters for Procedure

        Parameter setting: Hold the Set key until the light for

 setting temperature is On. Press the Set key each time for 

each menu setting (Recyclable  operation). After enter

menu, press        or       to change the parameter.

EW-285A Directions

Microcomputer Thermostat Serial

Code:285.16.08.16

Technical Specifications

1

:  AC220V      

±

10

    50HZ/60HZ

2

: 10A/220V/AC

3

: ≤

3W   

4

10

℃ ~

50

    R H

90%

5

:—

0.0

℃ ~

50.0

6

: .

1

       

:± . ℃

7

Input signal

:

8

×

×

9

×

Operating voltage

Output Load 

Power Consumption

Working environment

Control Range

5

Resolving Power

0

Accuracy

0 5

Overall Dimension

120(length)

53(wide)

84(high)mm

Starter Size:   92(length)

44(wide)mm

 one-way storage temperature sensor, 

     one-way defrosting sensor     10Kx2Mx2

Evaporator

Thermal insulating material

Defrosting sensor

Low-voltage air-return pipe

Appearance Panel

Wiring diagram

Press the Set key again

Hold the Set key for 6 seconds

Both hold the key        and       
for 6 seconds.

Press the Set key again

Press the Set key again

Hold the Heat key [forcing to
 defrost] for 6 seconds 

Press the Time key 
[remaining time ]

Press the Heat Temp key
 [defrosting temp. display ]

Press the Set key again

Press the Set key again

Temperature setting light On

The return difference 
temperature light On

Defrosting time light On

Run cycle light On

Delay time light On

Exit defrosting temperature 
light On 

All indicator lights are bright

None indicator light is bright

None indicator light is bright

Defrosting light On

Setting range: 5.0

35.0

Setting range: 

50.0

50.0

Setting range: 1

99 hours

Setting range: 1

5 minutes

Setting range: 1

45 minutes

Setting range: 0.11

15.0

Indicator light

Operation

Functions

Display

6 hour

10.0

5.0

3 minute

10 minute

3.0

The controller would firstly start the automatic defrosting 
function, then automatically operates according to the 
primeval settings. 

Display temperature of the defrosting sensor

It displays the remaining time in the run cycle during
refrigeration, while displays defrosting remaining time
when it defrosts.

Temperature correction settings:

15.0

15.0

Factory setting

Press the Set key on display the
primeval settings, then press
        or        can change the 
settings, and finally the 
controller will run auto-
matically to the new parmeter.

Larger digital means hours
Smaller digital means minutes

Larger digital displays

Demand of install

1.The voltage must accord with controller's demand. 
    The voltage's deviation  is no more than 

±

5%.

2.The sensor line must keeps away from the power line.
3.Must distinction the interface with the  sensors, power 
and output relay.

The sensor is installed the distance 5-10cm.

Demand of install

Larger digital displays

heat

temp

heat

time

up

set

down

    Welcome to choose our instruments. This product is 
a specialize micro-computer temperature  controller for 
refrigerator and freezer. The panel in English takes it 
easy to use and avoid entering confusing menu repre-
sents the parameter setting. Our sensor is precisely ma-
de and sealed. It is moisture proof, therefore its perfor-
mances are more stable and reliable. 

220V/AC

220V/AC

1 2 3 4 5 6 7 8 9 0 1

1

1

1

1

1

12 3 4 5

10A/220V/AC

 Output Load:

10A/220V/AC
            

Model:

EW-285A

D

efrost

sensor

Storehouse 

sensor

C

om

pr

es

so

r

D
e

f

r

o

s

t

Reviews: