background image

Lights NO

.

Function

Setting

 

range Ex-factory 

Value

Unit

NO.1Indicator

NO.1.2 Indicator

NO.2 Indicator

NO.3 Indicator

NO.4 Indicator

Temperature

 

difference

start

-

up

Temperature 
difference

High temperature 
correction

Low temperature 
correction

 

Temp

.

difference

of

 

stopped

 

pump

+

1

5

0

1

20

-10

10

-10

10

5

5

0

2

0

Wiring Diagram

Failure

Causes

Precautions

No display when power 

is on.

Check if the power is broken or the 

thermostat failture. 

Check power supply and change fuse.

Check if the input voltage is right or 

change the thermostat with our distributor. 

Displaying but machine 

doesn't work 

The setting  temperature is lower than the 
present temperature.
The heat protector is open circuit because the 
pressure is over loads.

Reset the necessary controlling temperature.
Check the reasons for overload and overheating. 
After the trouble is solved, restart to work.

Displayed temperature is

unstable or there exists 

misplay.

The sensor is interfered; or poor wiring; 

or Together with other power cord bundle

or line damage. 

Separate sensor wiring with power cables 

or change shielded lines or check if the contact

is tight or not.

Measurement error between 
current temperature and 
displayed.

The installation position of the sensor is not 
correct; or the sensor's wiring is too long and
its resistance is over; or the wiring connected 
poor; or the sensor is damaged

All sensors should be corrected at their locations. 

Enlarge the cross section of the expanded wires. 

Make sure the wires sealed is good. or Change the 

sensor. 

Machine does not stop 
when the temperature
reaches.

The sensor is not correctly installed and cannot
measure the correct temperature. Compressor 
contactor fails.

Check if the sensor has accurately measured

the temperature or not. Change compressor 

contactor.

Relay work with overload 

“EH” or “EL” is displayed

Return difference value is too small or the 

setting for pressure protection is not correct.

The sensor is opened or shorted circuit. 

Reset and enlarge return difference value. Adjust
setting for pressure protection.

Check to see if the sensor wiring has good contact 
with coupling end or not.

Stop the pump
 temperature

1

temp

.

difference

started

-

1

High

-

temp

.

Sensor

Low

-

temp

.

Sensor

Model: EW-M801AH

Output

 

load

220V/AC

5A                  5A

220V/AC

1 2 3 4

5

6

7

8

9 10 11

Controlled
Heating

Water

 

pump

circulation

Note: When the temperature difference is set at 0, the electric power is entered
           into the heating state.
           At the same time, press the set key and             key 6 seconds will restore 
           the factory settings

Parameters for Procedure

Trouble shooting 

NO.3.4 Indicator

Heating temperature
 difference

0

20

5

Warnings

1. Please read this product instruction carefully and connect 

input/output plugs of power & sensor to the  corresponding sockets 

strictly by following connection diagram, otherwise the usage & 

operations will   be affected. Check again to make sure there is no 

mistake. Tighten all the screw of connection plugs again, and then 

connect it to the power for running.

2. Keep away this product from moist or corrosive air and high 

magnetic field. Otherwise the normal  operation of this product will 

be affected.
.

3. All our products have passed strict quality inspections before 

leaving factory. We provide one-year quality guarantee (which is 

limited to product itself ,and is not responsible for any other joint 

and several liability) period for this product.

    If you have any doubt or problem concerning the electronic 

temperature or humidity controller made by us, please contact 

our distributors and we will provide you high-quality after-

sale services. Thanks!

Guangzhou Eliweli Autocontrol Tech. Co., Ltd.

 

http://www.eliweli.com

          If the products including but not limited to, the following is 

not the product itself quality problem caused by the damage, 

Install and use under the do not conform to the safe environment; 

That the load capacity is beyond the scope of product is allowed; 

Products by users to disassemble and change, change the internal 

components, etc.,We will not be so and damaged products 

provide a replacement and maintenance services, regardless of 

whether its in the quality assurance period; Meanwhile, we will 

not assume so direct or indirect losses caused by the liability to 

pay compensation.
        Product warranty date on the case is important basis of 

product quality assurance. Appeared including but not limited to 

full filling without permission, to change, to replace lost, 

damaged, scratched, dirty, and so on, we will not provide a 

replacement and maintenance services for these products.

Reviews: