Design and function
MIG/MAG welding
30
099-005593-EW501
10.01.2022
• Rotate the tommy by 90° clockwise or anti-clockwise (tommy locks into place).
• Fold the closure brackets outwards by 90°.
• Unfasten pressure units and fold out (clamping units and pressure rollers will automatically flip up-
wards).
• Remove the wire feed rollers from the roller support.
• Select new wire feed rollers accoridng to the Wire feed roller overview table and reassemble the wire
feed mechanism in reverse order.