Design and function
MMA welding or gouging
34
099-005593-EW501
10.01.2022
5.3.5 MIG/MAG special-torches
5.3.5.1 Switching between Push/Pull and intermediate drive
WARNING
Do not carry out any unauthorised repairs or modifications!
To avoid injury and equipment damage, the unit must only be repaired or modified by
specialist, skilled persons!
The warranty becomes null and void in the event of unauthorised interference.
• Appoint only skilled persons for repair work (trained service personnel)!
Dangers resulting from failure to perform test after conversion!
Before reconnection, “Inspection and Testing during Operation” according to
IEC/BS EN 60974-4 “Arc welding systems – Inspection and Testing during Operation”
has to be performed!
• Perform test to IEC / DIN EN 60974-4!
The plugs are located directly on the M3.7X printed circuit board.
Plug
Function
on X24
Operation with Push/Pull welding torch (factory setting)
on X23
Operation with intermediate drive
5.3.6 Welding task selection
For selection of the welding task and for general operation see the relevant Control operating instructions.
5.4 MMA welding or gouging
5.4.1 Connection of electrode holder or gouging torch
Figure 5-19
Item Symbol Description
0
1
Electrode holder
2
Gouging torch
Note the additional system documents!
3
Connection socket, welding current
Welding current potential of the torch connector for MMA welding or gouging