Rectifying faults
Error messages (power source)
94
099-005507-EW501
13.09.2018
7.2
Error messages (power source)
A welding machine error will be signalled by an error code (see table) on the control display. In
the event of an error, the power unit shuts down.
The display of possible error numbers depends on the machine version (interfaces/functions).
• Document machine errors and inform service staff as necessary.
• If multiple errors occur, these are displayed in succession.
Error
(Err)
Category
Possible cause
Remedy
a)
b) c)
1
-
-
x
Mains overvoltage
Check the mains voltages and compare with
the welding machine connection voltages
2
-
-
x
Mains undervoltage
3
x
-
-
Welding machine excess
temperature
Allow the machine to cool down (mains
switch to "1")
4
x
x
-
Coolant error
Fill coolant
Turn on pump shaft (coolant pump)
Check air cooling unit overcurrent trip
5
x
-
-
Wire feeder/tachometer error
Check the wire feeder
Tachogenerator is not emitting a signal,
M3.51 defective > inform Service.
6
x
-
-
Shielding gas error
Check shielding gas supply (for machines
with shielding gas monitoring)
7
-
-
x
Secondary overvoltage
Inverter error > inform Service
8
-
-
x
Wire error
Separate the electrical connection between
welding wire and casing or an earthed object
9
x
-
-
Quick shut-down
Rectify error on robot
(Interface for automated welding)
10
-
x
-
Arc interruption
Check wire feeding
(Interface for automated welding)
11
-
x
-
Ignition error (after 5 s)
Check wire feeding
(Interface for automated welding)
13
x
-
-
Emergency stop deactivation
Check the emergency stop switch at the
interface for automated welding
14
-
x
-
Wire feeder detection
Check cable connections
ID number allocation error
(2DV)
Correct ID numbers
> see 5.3 chapter
15
-
x
-
Second wire feeder detection
Check cable connections
16
-
-
x
Open circuit voltage reduction
error (VRD)
Inform Service.
17
-
x
x
Overcurrent detection on wire
feeder
Check ease of wire feeding
18
-
x
x
Tachogenerator signal error
Check the connection and particularly the
tachogenerator of the second wire feeder
(slave drive).
56
-
-
x
Mains phase failure
Check mains voltages
59
-
-
x
Machine incompatible
Check machine usage
> see 3.2 chapter
60
-
-
x
Software update required
Inform Service.