Appendix
Parameter overview – setting ranges
80
099-00L200-EW501
13.05.2022
8.1.1.1 Pulse parameters
Name
Display
Setting range
Co
de
S
tand
ar
d
Un
it
min
.
max.
Pulse current (average value pulsing)
140
%
1
200
Pulse time (thermal pulsing)
0,01
s
0,00
-
20,0
Pulse pause time (thermal pulsing)
0,01
s
0,00
-
20,0
Pulse balance (average value pulsing, AC and DC)
50,0
%
0,1
-
99,9
Pulse frequency (average value pulsing, DC)
2,00
Hz
0,10
- 20000
Pulse frequency (average value pulsing, AC)
2,00
Hz
0,10
-
5,00
8.1.1.2 AC parameters
Name
Display
Setting range
Co
de
S
tand
ar
d
Un
it
min
.
max.
Balance
65
%
40
-
90
Frequency
50
Hz
30
-
300
AC commutation optimisation
auto
1
-
100
Amplitude balance
100
%
70
-
160
8.1.2 MMA welding
Name
Display
Setting range
Co
de
S
tand
ar
d
Un
it
min
.
max.
Hot start current (per cent of
)
120
%
1
-
200
Hot start current (absolute, power source dependent)
-
A
-
-
-
Hot start time
0,5
s
0,0
-
10,0
Main current (power source dependent)
-
A
-
-
-
Arcforce
0
-40
-
40
JOB presets
-
101
-
108
JOB presets (CEL)
-
109
-
116