Appendix
Parameter overview – setting ranges
099-00L200-EW501
13.05.2022
81
8.1.2.1 Pulse parameters
Name
Display
Setting range
Co
de
S
tand
ar
d
Un
it
min
.
max.
Pulse current (average value pulsing)
142
1
-
200
Pulse balance (average value pulsing, AC and DC)
30
%
0,1
-
99,9
Pulse frequency (average value pulsing, DC)
1,2
Hz
0,1
-
500
Pulse frequency (average value pulsing, AC)
1,2
Hz
0,1
-
5
8.1.2.2 AC parameters
Name
Display
Setting range
Co
de
S
tand
ar
d
Un
it
min
.
max.
Frequency
100
Hz
30
-
300
Balance
60
%
40
-
90
8.1.3 Global parameters
Name
Display
Setting range
Co
de
S
tand
ar
d
Un
it
min
.
max.
Standby
20
m
5
-
60
Re-ignite after arc interruption
Job
s
0,1
-
5
Torch mode
1
-
1
-
6
Up/down speed
10
-
1
-
100
Current jump
1
A
1
-
20
Retrieval of JOB number
100
-
1
-
100
Start JOB
1
-
1
100
Minimum current for foot-operated remote control
(AC)
10
A
3
-
50
Torch cooling, follow-up time
7
-
1
-
60
Torch cooling, temperature error limit
70
C
50
-
80
Torch cooling, temperature error limit (imperial)
158
F
122
-
176
Torch cooling, flow error limit
0,6
l
0,5
-
2,0
Torch cooling, flow error limit (imperial)
0.16
gal
0.13
-
0.53
Dynamic power adjustment
16
-
10
-
32
Arc detection for welding helmets (TIG)
0
-
0
-
2