Design and function
Special parameters (advanced settings)
099-005504-EW501
20.11.2015
87
Mean value display for superPuls (P19)
Function active (P19 = 1)
• For superPuls, the performance
mean value
from program A (P
A
) and program B (P
B
) is shown on the
display (ex factory).
Function inactive (P19 = 0)
• Only the performance of program A is displayed for superPuls.
If the function is enabled and only "000" is shown on the machine display, this is a rare case of
an incompatible system set-up. Solution: Disable special parameter P19.
Predefined execution of the pulsed arc welding process in the PA program (P20)
For machine versions with pulsed arc welding procedures only.
Function active (P20 = 1)
• If the superPuls and welding process switching functions are available and activated, the pulse arc
welding process is always executed in the main program PA (ex factory).
Function inactive (P20 = 0)
• Predefined execution of the pulse arc welding process in the PA program is disabled.
Predefined absolute value for relative programs (P21)
Start program (P
START
), down-slope program (P
B
) and end program (P
END
) can be set relative to the main
program (P
A
) or in an absolute manner, as desired.
Function active (P21 = 1)
• Absolute parameter setting
Function inactive (P21 = 0)
• Relative parameter setting (ex factory)