background image

eWON

 2101CD™

Installation Guide

ver 1.6

page 12 of 34

 3.4 Equipment information and versions

The eWON hardware and software revisions can be checked with a web browser on the eWON server. Once 
logged onto the eWON, clicking on the eWON logo shows these revisions.

Figure 3: eWON info page details

IP address

Software 

version

Serial number

System Info:

IO rev, Modem 

type, free mem

Summary of Contents for 2101CD

Page 1: ...eWON 2101CD Installation Guide Rev 1 6 Cool Internet Telecontrol Solutions VPN Router Remote Access Server RAS Programmable Industrial Router PIR ...

Page 2: ...Mounting and environmental conditions 14 3 7 Preparing the installation 14 3 8 Specification for external power supply selection 14 3 8 1 Auto fuse 15 4 Front panel control LEDs 15 5 Specifications of communication interfaces and I Os 16 5 1 Ethernet Port 16 5 2 Embedded PSTN 56k Modem optional 16 5 3 Embedded ISDN Modem optional 16 5 4 Embedded GPRS EDGE quad band Modem optional 17 5 4 1 SIM card...

Page 3: ...eWON 2101CD Installation Guide ver 1 6 8 5 Serial Port 31 8 6 MPI port 32 8 7 PSTN ISDN phone line connector 33 8 8 Antenna 33 8 8 1 Connector specifications 33 8 8 2 Antenna specifications 34 ...

Page 4: ... ownership 1 2 General specification of the hardware platform Processor ARM clocked 75Mhz 16Mb SDRAM 32Mb Flash Backed up real time clock RTC with 24 Hours autonomy Battery with 10 years autonomy for RTC External power supply 12 24 VDC 20 consumption 10W max 1 Ethernet port 10 100Mb BaseTx 1 Serial port configurable in RS232 RS422 RS485 OR 1 MPI port up to 12 Mbits sec 1 digital input DI 1 digital...

Page 5: ...Router functions Automatic routing of protocols Programmable routing from I O and Tag names BASIC 1 4 Typical applications Alarm management Sending alarms by network phone Email and or SMS Remote measurements loop back control and monitoring Predictive and operational maintenance Diagnosis and machinery status control Process and machinery activity logs Commissioning support Remote programming Int...

Page 6: ...422 RS485 serial port 6 MPI port m Modem 3 ISDN EU modem 4 PSTN 56k modem 8 GPRS quad band A HSUPA modem B UMTS Global Examples of Part Numbers for the eWON2101CD platform Type Description Part Number eWON2101CD ISDN ISDN modem EW33203 eWON2101CD PSTN 56 PSTN 56 modem EW33204 eWON2101CD GSM GPRS GSM GPRS modem EW33208 eWON2101CD HSUPA HSUPA modem EW3320A eWON2101CD UMTS UMTS Global modem EW3320B e...

Page 7: ...cations conformity to standards Installation recommendations and pinout of the connectors Exists for each eWON type 2 Software Reference Guides Exhaustive reference guides to use all advanced functions of the eWON General Reference Guide RG 001 Programming Guide RG 002 Web reference guide RG 003 3 Application User Guides Guides covering one application topic For examples eWON Getting Started eWON ...

Page 8: ...ge 8 of 34 3 Housing and markings 3 1 Housing Interfaces WAN PPP port phone line Reset button hole Serial port or MPI port LAN ETH port Ethernet 10 100 Digital IO Power Ground Din rail latch SimCard GSM antenna connector Leds Figure 1 Housing ...

Page 9: ...h memory This SN is also used in order to scan the network for eWONs and to assign its IP address subnet mask and gateway For more details See Equipment information and versions on page 12 Serial Number 1334 year week 0002 sequential number 44 suffix eWON2101CD Device Type and Optional modem PSTN PSTN modem at 56kb GPRS QB GPRS quadband modem UMTS Global UMTS global MAC address and IMEI for GSM Fi...

Page 10: ... or service battery Do not dispose of batteries in a fire or with household waste 3 3 4 FCC Compliance The eWON2101CD range including optional modems complies with Part 15 of the FCC Rules Operating is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired opera...

Page 11: ...rally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between radiating structures and the body of the user or nearby persons 3 3 5 Certifications Please check our http wiki ewon biz Support page to get the current versions of Declaration of Conformity DoC Other official documents including certificate ...

Page 12: ...rsions The eWON hardware and software revisions can be checked with a web browser on the eWON server Once logged onto the eWON clicking on the eWON logo shows these revisions Figure 3 eWON info page details IP address Software version Serial number System Info IO rev Modem type free mem ...

Page 13: ...0022 To put the unit in place insert the upper slider into the upper part of the rail with the eWON tiled around 20 Then push and rotate the eWON downward to put the unit right The eWON2101CD is now safely fastened For HSUPA modem the SIM card drawer is located on eWON top side See Embedded HSUPA modem optional on page 19 39 mm 129 mm 108 m m Ground DIN rail latch SIM card drawer upper slider ...

Page 14: ...ts lightning protection and to conform to the EMC requirements Therefore a ground screw is available at the top of the unit Connect this screw directly to a low impedance ground 3 8 Specification for external power supply selection The eWON2101CD has to be supplied by an external voltage source ranging from 12 to 24 VDC The power supplied must be a Class 2 or Level 3 SELV compliant Safety Extra Lo...

Page 15: ...ease check the device for presence of loose metal parts inside likely to generate a short circuit If the problem recurs even after such a verification then return the device to the vendor for further investigation 4 Front panel control LEDs POWER green ON PS 12 24 VDC present SERIAL green flashing activity RX DI Input green ON logic 1 MODEM green ON DCD connected line USER bicolor Hardware status ...

Page 16: ...ossed cables 5 2 Embedded PSTN 56k Modem optional 5 3 Embedded ISDN Modem optional Specification Value Applicable standard 10 100BaseTX Isolation 1 5 kV Pinout RJ45 connector See label and appendix RJ45 connector on page 29 Table 4 Ethernet port specification Specification PSTN Max baud rate V92 56 kbps Pinout phone line connector See label and appendix PSTN ISDN phone line connector on page 33 Le...

Page 17: ...hould be used as a reference See Antenna on page 33 5 4 1 SIM card installation SIM card eject button SIM card drawer Figure 6 SIM card insertion Specification GPRS EDGE Bands Quad band EGSM 850 900 1800 1900 MHz E GPRS Class Class 10 Max baud rate 115 kbps Compliant to standards R TTE CE FCC Certificate number Antenna connector Type SMA F Table 7 GPRS QB modem specification ...

Page 18: ...e 33 5 5 1 SIM card installation SIM card eject button SIM card drawer Figure 7 SIM card insertion Specification UMTS Global Bands Quad band EGSM 850 900 1800 1900 MHz Tri band UMTS HSDPA 850 1900 2100 MHz Class GPRS Multi slot Class 12 EDGE Multi slot class 12 Max baud rate 230 kbps Compliant to standards R TTE CE FCC Certificate number Antenna connector Type SMA F Table 8 UMTS Global modem speci...

Page 19: ...IM card installation HSUPA modem For HSUPA modem only the SIM card drawer is located on the top of the eWON Specification HSUPA Bands Quad band EGSM 850 900 1800 1900 MHz Tri band UMTS HSUPA 850 1900 2100 MHz Class GPRS Multi slot Class 12 EDGE Multi slot class 12 Max baud rate 921 kbps Compliant to standards R TTE CE FCC Certificate number Antenna connector Type SMA F Table 9 HSUPA modem specific...

Page 20: ...y OFF Note that switch 3 4 need to have the same position both ON or both OFF When they are ON it connects the internal polarisation typ 680 Ohms and termination typ 120 Ohms resistors This configuration applies only to RS485 RS422 lines conforming to good practices Specification Value Physical modes configurable RS232 RS485 RS422 Isolation Not isolated Pinout connector See label and appendix Seri...

Page 21: ...en the input is ranging between 5 and 10VDC Specification Value Physical mode MPI Speed 9 6 kBauds 19 2 kBauds 45 45 kBauds 93 75 kBauds 187 5 kBauds 1 5 MBauds 3 0 MBauds 6 0 MBauds 12 0 MBauds Polarisation 100 kOhms Termination None Pinout connector See label and appendix MPI port on page 32 Specification Value Input voltage range 0 to 24 VDC Input voltage absolute max varistor protection 33 VDC...

Page 22: ...supplied from an external source to the pre drive electronics The diagram below shows the external wiring needed for correct operation of the digital output A relay has been chosen for this sample application but any load within the specifications can be used instead Warning note that this is a sink only output to ground the transistor acts like a switch to ground Figure 9 Digital output wiring di...

Page 23: ...etwork and will identify all eWONs that are connected including their IP parameters Address and subnet mask and their serial number The utility allows also to edit the IP parameters IP parameters always have to be defined in full agreement with network policies applicable within your organisation ask your network administrator Default settings note By default the incoming PPP connection is allowed...

Page 24: ...and IP addresses Return to ex factory configuration default config Full hardware auto test with result shown by the USER LED You generate this second level reset by pressing and maintaining the reset button during approximately 20 secs after powering up the eWON until the USER LED remains RED continuously When this state is reached release the button and wait approximatively during 90 seconds unti...

Page 25: ... also find usefull documentation at http support ewon biz 8 Appendix Pinouts and connections 8 1 Power Supply 2 1 Figure 10 Power supply connector eWON Mating female connector included Manufacturer Phoenix Contact GmbH http www phoenixcontact com Part Number GMSTB 2 5 2 STF 5 08 Pinout see label Pin Description 1 Ground 2 Positive Table 16 Pinout Power Supply Connector ...

Page 26: ...ed These cables have 8 copper conductors and are known as UTP Class 5 with RJ45 terminations at both ends The type of cable straight or crossed depends on the equipment the eWON will be connected to The most current cases are the direct connection with a PC crossed and the connection through a hub router straight The WAN port have 2 leds showing the state and activity on the port color activity Me...

Page 27: ...nterface is not autosense then you must use a crossed ethernet cable to make a direct WAN connection When cabling over long distance you have to take care of the twisted pairs This means that along with the above cabling conventions the emission TX TX and reception RX RX signals have to be connected on the same twisted pair Pins 4 5 7 and 8 do not have to be connected The following picture shows t...

Page 28: ...n over hub router If the eWON is connected to a hub it has to be connected like any other device with a straight cable Again the wiring is as shown on the following picture and care should be taken to keep the RX and TX signals on twisted pairs Hub Router Straight cable ...

Page 29: ...WON 2101CD Installation Guide ver 1 6 page 29 of 34 8 3 RJ45 connector The RJ45 connector has got the following pins numbering as it can be seen on the following picture showing it from different angles ...

Page 30: ... CTF050VT Pin REF Description 1 DO_GND Output digital signal 0V ground connected to the emitter of the transistor 2 DO Output digital signal connected to the drain of the MOSFET transistor 3 DO_VDC Common of the external predrive power supply between 12 et 24 VDC 4 DI_GND Ground of the input isolated 5 DI Input digital signal Figure 11 Pinout I O connector ...

Page 31: ...of 34 8 5 Serial Port Mating female connector not included Pinout serial port according to mode Type Female DB9 with 4 40 blocking screws Pin RS232 RS485 RS422 1 2 RXD RX 3 TXD A TX 4 5 GND GND GND 6 7 RTS RX 8 CTS B TX 9 Table 18 Pinout serial port ...

Page 32: ...CD Installation Guide ver 1 6 page 32 of 34 8 6 MPI port Mating male connector not included MPI port pinout DB9 female Type Male DB9 with 4 40 blocking screws Pin MPI 1 2 3 B 4 5 GND 6 7 8 A 9 Table 19 MPI port ...

Page 33: ...cifications For eWON with GSM GPRS EDGE HSUPA modem the antenna connector is placed on the top of eWON Type RJ11 type 6P2C without shield Pin Description 1 2 3 TIP 4 RING 5 6 Table 20 pinout PSTN modem Pin Description 1 2 TX 3 RX 4 RX 5 TX 6 Table 21 ISDN connector pinout Specification Value Type SMA F Tightening Torque MAX 0 5N m manual tightening should be used as a reference Table 22 Antenna co...

Page 34: ...S EDGE HSUPA modem the antenna specification is as follows Specification Value Type Quadband 850 900 1800 1900 MHz Impedance 50 Ohms Gain Antenna used must not exceed a gain of GPRS 1 4 dBi 850 MHz 3 0 dBi 1900 MHz UMTS 3 0 dBi all frequencies HSUPA 2 0 dBi all frequencies Table 23 Antenna specifications ...

Reviews: