EX-TECH-SIG-SAS-12-SD125-150-TM-EN-REV04 

 

1.0        INTRODUCTION

 

 

SD-150/125  series  Explosion-proof  Sounder/Horn  & 

Loudspeaker  is  designed  according  to  EN  / IEC   

60079-0,  EN  / IEC  60079-1  and  EN  54  (SB  5879) 

standard.  Enclosure  material  is  UV  and  corrosion 

resistance  GRP  (Glass Reinforced  Polyester).  This 

product  certified  for  use  and  installation  in  Zone  1  and 

Zone  2  areas  with  gases  groups of  IIA,  IIB,  IIC  and 

temperature  classification  of  T4~T6.  The SD 125 version 

is made in SS  316 and the SD 150 version is made in 

GRP.

 

Users  can  choose  single  sounder,  speaker  or  two-in-one 

sounder & loudspeaker. The design of two-in-one sounder 

& loudspeaker is unique. According to user control system, 

4  stages  of  alarm  tones  can  be  sent  out.  63  tones  are 

selectable. Users can record sounds or customize sounds 

into  the  sounder  by  using  5  spare  tones.  Tone  can  be 

preset during installation. 

 

2.0        EXPLOSION-PROOF LABELING

 

 

All products have a rating label, which carries the following 

important information: 

 

Product order no.: e.g. 

SD150DCNNARDN

 

 
(Refer to the datasheet for product order selection) 

Input voltage: up to 48V DC or 100-254V AC 

Code: SD150-1101400001 

Ex d IIC Txx Gb 

Ex tb IIIC Txx 

ATEX Marking:   

 

        

Gas Group and Category: II 2GD 

CE Mark: 

 

 

        

  

   

Warning: 

  

DO NOT OPEN WHEN AN EXPLOSIVE GAS 

ATMOSPHERE IS PRESENT

 

Finish product serial no. (Include date of construction) 

Note; exact information is given on the actual label, 

ref also example on page 1.

 

3.0        TYPE APPROVAL STANDARD

 

The BC series products have been approved according the  

following standards: 

IEC/EN 60079   General Requirements  

IEC/ EN 60079-1  Flame proof Enclosure‘d’ 

IEC/ EN 60079-31  Dust atmosphere “t” 

 

4.0 

ZONES, GASGROUP, CATEGORY AND 

TEMPERATURE CLASSIFICATION

 

 

The  BC  series products have been certified Ex d IIC T4~T6. 

This means that the units can be installed in locations with the 

following conditions: 

Area Classification:   

Zone 1

:  Explosive gas air mixture likely to occur in normal 

operation. 

 

Zone 2:

 Explosive gas air mixture not likely to occur, and if it 

does, it will only exist for a short time. 

Gas Groupings:

 Group IIA Propane Group  

                                       IIB Ethylene Group  

                                       IIC Hydrogen and Acetylene   

Equipment Category:

 ATEX, 2GD  

EPL; Gb/ Db 

Temperature Range: 

 See label, ref page 1   

 

5.0  INSTALLATION

 

 

General Requirement

 

 

Selection, Installation,  Maintenance  and repair of electrical 

apparatus for use in potentially  explosive atmosphere  should 

be done in according to IEC/ EN 6079-14/  -17/  -19  .  Product 

installation must be carried out in accordance with  any local 

codes that may apply and should only be carried out  by a 

competent electrical engineer. 

Location

 

 

The  location  of  the  unit  should  be  made  with  due  regard  to

Summary of Contents for SD125

Page 1: ...P66 Ex tb IIIC Txxx EX TECH SIGNALLING SAS SD125 150 EXPLOSION PROOF SOUNDER HORN TECHNICAL MANUAL Marking details Please note that every care has been taken to ensure the accuracy of our technical ma...

Page 2: ...Warning DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS PRESENT Finish product serial no Include date of construction Note exact information is given on the actual label ref also example on page 1 3...

Page 3: ...ioned such that dust debris or water cannot enter into the horn opening but operate in reverse manner as above 6 0 WIRING General Requirement EX TECH SIGNALLING SAS recommends that all cables and core...

Page 4: ...m EX TECH SIGNALLING SAS in advance before EX TECH SIGNALLING SAS begin the production of the sounder 11 0 CABLE GLAND 8 0 VOLUME CONTROL The sounder has a volume control to adjust the output volume o...

Page 5: ...exterior of the product can be cleaned with a damp cloth If spare parts are required these can be supplied by EX TECH SIGNALLING SAS Company SAFETY WARNING In the case of Anti Static and UV Resistant...

Page 6: ...EX TECH SIG SAS 12 SD125 150 TM EN REV04 Attached Table 2 Tone Selection Table 6...

Page 7: ...S 12 SD125 150 TM EN REV04 EX TECH SIGNALLING SAS ZA Les Montagnes 355 rue de la G noise 16430 CHAMPNIERS France Tel 33 5 45 61 81 68 Fax 33 5 45 23 29 46 Website www ex tech no E mail sales signallin...

Page 8: ...Hz 2s on 2s off Intermittent Air raid Sweden 105 101110 890 86 30 700Hz 125ms on 125ms off Intermittent Local Warning Sweden 105 011110 875 87 31 720Hz 0 7s on 0 3s off Intermittent Industrial alarm G...

Page 9: ...is on 4 The unit will alarm as stage 1 when switch 1 is on The unit will alarm as stage 2 when switch 2 is on The unit will alarm as stage 3 when switches 1 2 are on Telephone Initiated PCB Function...

Page 10: ...The unit will alarm as stage 2 when switch 2 is on The unit will alarm as stage 3 when switches 1 2 are on Telephone Initiated PCB Function 1 Connect the telephone line to the Tel terminals 2 The unit...