  Replace  the  battery  only  with  another  battery  that  has  been  qualified  with  the  unit.  Use  of  an 

unqualified battery may present a risk of fire, explosion, leakage, or other hazard.  

  Promptly dispose of used batteries in accordance with local regulations.  

  Children should not touch battery and charger.  

  Avoid  dropping  the  battery  and  charger.  If  the  battery  or  charger  is  dropped,  especially  on  a  hard 

surface, and the user suspects damage, contact ExaDigm for inspection.  

  Improper battery or charger use may result in a fire, explosion, or other hazard. 

18.0 

Regulatory Notices and Certifications 

18.1 

Part 15 of FCC Rules 

FCC Part 15 Class B Digital Device  

The NX1200 has been tested and found to comply with the limits for a Class B digital device, pursuant to 
part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful 
interference in a residential installation. This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause harmful interference 
to  radio  communications.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can 
be  determined  by  turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the 
interference by one or more of the following measures:  

  Reorient or relocate the receiving antenna.  

  Increase the separation between the equipment and receiver.  

  Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  the  receiver  is 

connected.  

  Consult the dealer or an experienced radio/TV technician for help.  

Operation  of  the  NX1200  in  a  residential  installation,  per  Part  15  of  the  FCC  rules,  is  subject  to  the 
following two conditions:  

1. This device may not cause harmful interference, and  

2. The device must accept any interference received, including interference that may cause undesired 

operation.

 

18.2 

Part 68 of FCC Rules 

This equipment complies with the regulations in Part 68 of the FCC Rules. The FCC registration number 
and REN (ringer equivalence number) is located on the FCC label located in the back of the terminal. 
The  REN  is  used  to  determine  the  quantity  of  devices  that  may  be  connected  to  the  telephone  line. 
Excessive RENs connected to the telephone line may result in the device not being able to communicate. 
Contact the telephone company to determine the maximum RENs for the calling area. 
This  equipment  cannot  be  used  on  telephone  company  provided  coin  service.  Connection  to Party  Line 
Service is subjected to state/local fees. 
The equipment uses RJ11C jacks. 

Summary of Contents for NX1200

Page 1: ...arranty of any kind with regard to this material including but not limited to the implied warranties or merchantability and fitness for a particular purpose ExaDigm shall not be liable for errors cont...

Page 2: ...0 NFC Contactless 7 10 0 Modem Configurations 7 Dial 7 GSM GPRS 7 Ethernet 7 WiFi 7 11 0 Connecting External Readers 8 12 0 Alpha Numeric Keypad 8 13 0 Color Coded and Function Keys 9 14 0 Terminal Fu...

Page 3: ...ptacle on the left side of the terminal and secure it to a live electrical outlet Certain conditions may damage the terminal or cause it to operate poorly In general avoid areas with Excessive heat or...

Page 4: ...orts used to connect the terminal to a power source Ethernet port PIN pad and the RS 232 port for additional cables NFC Contactless Magnetic Card Reader Screen Power ON OFF Up Down Arrow Cancel Key 2...

Page 5: ...X1200 uses thermal 2 x 80 paper rolls standard size Follow the steps below to install a paper roll 1 Place forefinger under flap at the top of the terminal and pull forward using force 2 Using the tab...

Page 6: ...ly use your fingernail or a small flathead screwdriver to slide the gate from the LOCKED to the UNLOCKED position slide to the right to unlock The distance required is about 1 8 inches or 3mm 3 Once u...

Page 7: ...SO or ExaDigm to confirm activation Ethernet Connect the Ethernet cable to the Ethernet port LAN on the back of the terminal WiFi Connect the mini USB stick to the USB port on the side of the NX1200 I...

Page 8: ...esponding number and continue depressing until the letter is displayed Number Alpha 1 Alpha 2 Alpha 3 Alpha 4 Alpha 5 Alpha 6 1 Q Z q z 2 A B C a b c 3 D E F d e f 4 G H I g h i 5 J K L j k l 6 M N O...

Page 9: ...Key This key will move the cursor to the right of a text character Up Arrow Key Press this key to move up in a menu and move to the far left in a text box Down Arrow Key Press this key to move down i...

Page 10: ...r the other options Action Hot Keys Void CLEAR Go to specific transaction record number F1 and ENTER Move to the last transaction F1 and Move to the first transaction F1 and Delete F1 and CLEAR Reprin...

Page 11: ...user delete or edit current user or print users list in user management menu 15 1 1 Roles Users are assigned to a specific role when they are created Currently 3 predefined levels of roles are availa...

Page 12: ...t must be a minimum of 7 and a maximum of 20 characters If the requirement is not met the terminal will display an error message and the user will be forced to try again User passwords expire every 90...

Page 13: ...ative hours for example 720 equals 30 days The maximum value is 9999 To set the retention period follow the instructions below 1 From Payment App menu 2 Go to Admin 3 Go to App Setup 4 Go to Security...

Page 14: ...essed by any user The settings are based on PA DSS requirements The following rules are applied in Database module PIN Block Data is not stored in any case CVV Data is not stored in any case Full Magn...

Page 15: ...ause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the f...

Page 16: ...to an AC surge protector to avoid damage to the equipment in the event of electrical surges To reduce the risk of fire use only a No 26 AWG or larger telecommunication line cord 18 3 UL Standards Fol...

Reviews: