XRT86VL38
PRELIMINARY
xr
OCTAL T1/E1/J1 FRAMER/LIU COMBO
REV. P1.0.6
159
5
LOSLFA_2_ENB
R/W
0
LOS/LFA 2 automatic transmission
This READ/WRITE bit-field enables the auto Sa-bit transmission
upon detecting Loss of Signal (LOS) or Loss of frame alignment
(LFA) condition.
Upon detecting Loss of Signal or Loss of Frame alignment condi-
tion, E1 framer will transmit the Alarm bit (A bit) as ‘1’, Sa5 bit as ‘0’,
and Sa6 bit as ‘0’ pattern.
See Table 69 for the transmit Sa5, Sa6, and A bit pattern upon
detecting LOS or LFA conditions.
4
LOSLFA_3_ENB
R/W
0
LOS/LFA 3 automatic transmission
This READ/WRITE bit-field enables the auto Sa-bit transmission
upon detecting Loss of Signal (LOS) or Loss of frame alignment
(LFA) condition.
Upon detecting Loss of Signal or Loss of Frame alignment condi-
tion, E1 framer will transmit the Alarm bit (A bit) as ‘0’, Sa5 bit as ‘1’,
and Sa6 bit as ‘1100’ pattern.
See Table 69 for the transmit Sa5, Sa6, and A bit pattern upon
detecting LOS/LFA conditions.
3
LOSLFA_4_ENB
R/W
0
LOS/LFA 4 automatic transmission
This READ/WRITE bit-field enables the auto Sa-bit transmission
upon detecting Loss of Signal (LOS) or Loss of frame alignment
(LFA) condition.
Upon detecting Loss of Signal or Loss of Frame alignment condi-
tion, E1 framer will transmit the Alarm bit (A bit) as ‘0’, Sa5 bit as ‘1’,
and Sa6 bit as ‘1110’ pattern.
See Table 69 for the transmit Sa5, Sa6, and A bit pattern upon
detecting LOS/LFA conditions.
2
NOP_ENB
R/W
0
No power automatic transmission
This READ/WRITE bit-field enables the auto Sa-bit transmission
upon detecting Loss of Power condition. The XRT86VL38 device
recognizes the Loss of Power condition by monitoring the Loss of
Power input pin (pin AB1). When the Loss of Power input pin is
HIGH indicates a Loss of Power condition is occurring. When the
Loss of Power input pin is LOW indicates no Loss of Power condi-
tion detected.
Upon detecting Loss of Power condition, E1 framer will transmit the
Alarm bit (A bit) as ‘0’, Sa5 bit as ‘1’, and Sa6 bit as ‘1000’ pattern.
See Table 69 for the transmit Sa5, Sa6, and A bit pattern upon
detecting Loss of Power condition.
T
ABLE
68: T
RANSMIT
Sa A
UTO
C
ONTROL
R
EGISTER
1 - E1 M
ODE
O
NLY
R
EGISTER
39 T
RANSMIT
S
A
A
UTO
C
ONTROL
R
EGISTER
1 (TSACR1) 0
XN
131
B
IT
F
UNCTION
T
YPE
D
EFAULT
D
ESCRIPTION
-O