27
CONVENIENCE
SECURITY
INST
ALLER ONL
Y
User Feature Programming: Ignition on, off, press valet 5 times
# Feature
Lock Button
(Brake x 1)
Unlock button
(Brake x 2)
Trunk button
(Brake x 3)
Start button
(Brake x 4)
Lock + Unlock
(Brake x 5)
1 Remote Start Run Time
10 min
5 min
15 min
20 min
2 Flashing Light Confirmations
Unlock: ON
RS: ON
Unlock: ON
RS: Flash
Unlock: Flash
RS: ON
Unlock: Flash
RS: Flash
3 Confirmation Chirp Volume
Low
Med-Low
Med-High
High
4 BROWN Wire: Siren / Pulsed Horn
Pulse LOW
Pulse MED
Pulse HI
Steady Siren
5 Ignition Lock / Unlock
Off
Ign On = Lock Ign. Off = Unlock Lock + Unlock
6 Door Open Bypass for Feat. #5
On
Off
7 Unlock w/ Trunk Release
On
Off
8 RS Activation (Remote)
Start x 1
Start x 2
Start x 3
Start x 4
9 Last Door Arming
Off
On w/o Lock
On w/ Lock
10 Automatic Rearming
Off
On w/o Lock
On w/ Lock
Enhanced
11 Confirmation Chirps
Siren + Horn Siren Only
On Demand
Off
12 Anti-Carjacking
Ignition
Door
Ig Door
Off
13 NOT USED
14 Ignition Override
On
Off
15 Alarm Trigger Duration
30 sec
60 sec
90 sec
120 sec
16 Arming Delay
3 sec
15 sec
30 sec
45 sec
17 Open Door Warning Upon Arming
On
Off
Installer Feature Programming: Ignition on, off, press valet 10 times
1 RS Activation (WHITE/BLUE wire)
1 Pulse
2 pulses
3 pulses
4 pulses
2 PINK/WHITE Wire
Ignition
Accessory
Starter
3 Engine Detection
Tachless Hi
Tachless Lo
Tach Wire
Data-tach
Crank Only
4 Gasoline or Diesel Engine
Gasoline
15 sec Diesel
20 sec Diesel
30 sec Diesel
5 Light Relay Function
Dome Light
Start
Ignition
Accessory
Status
6 Blue Sat Port BLUE Wire
Ignition
Status
Pulse After Start
below freezing
Pulse After
Engine Off
Horn
7 Crank Time
0.75 sec
1 sec
1.5 sec
2.25 sec
8 Door Lock/Unlock Outputs
0.8 sec
3 sec
Double Unlock
Total Closure
9 Remote Start Lock Control
Off
Lock after
Start
Unlock before
Start
Lock + Unlock
10 Turbo Timer
Off
1 min
2 min
3 min
11 Manual Transmission
On
Off
12 Data Port Protocol
Green: DBI
Black: DBI
Green: iData
Black: iData
Green: DBI
Black: iData
Green: iData
Black: DBI
Auto-detect
13 Alarm Functions
On
Off
14 Pulse Ign. on Disarm
On
Off
15 Lock On Prewarn
On
Off
16 Starter Interrupt
Alarm Only
Anti-grind Only Alarm/Anti-Grind Automatic
17 Low Temp Crank Extender
0 ms
200 ms
300 ms
400 ms
18 Arm/Disarm or CH. 4/5
Arm/Disarm
Arm/CH. 5
CH. 4/Disarm
CH. 4/CH.5
19 Horn Relay Function
Horn
Ignition
Trunk Release
Pulse After
Start