background image

7

6 Pin Secondary Wire Harness

PINK WIRE - 3RD CHANNEL (-) OUTPUT

 

This output provides a 250mA negative output when the CH3 function is activated by the con-

troller� The output will remain as long as the controller button(s) is held�

CONNECTION:

 Connect this wire to any desired add-on accessory that can utilize a negative 

activation input�

WHITE/BLUE WIRE - REMOTE START ACTIVATION (-) INPUT

 

This input will activate the system’s remote start function when it receives 2 negative pulses� 

Another 2 pulses during remote start operation will turn off the remote start� You can change this 

to a single pulse activation with user feature 17�

CONNECTION:

 Connect this wire to any device that you desire to activate remote start� 

WHITE WIRE - ALARM ARM (-) INPUT

 

This input will arm the system’s alarm when it receives a negative pulse�

CONNECTION:

 Connect this wire to any device that you desire to arm the alarm� It requires a 

negative pulse input�

BROWN WIRE - ALARM DISARM (-) INPUT

 

This input will disarm the system’s alarm when it receives a negative pulse�

CONNECTION:

 Connect this wire to any device that you desire to disarm the alarm� It requires a 

negative pulse input�

LT� GREEN/RED WIRE - OEM ALARM ARM / CH4 (-) OUTPUT

 

This output provides a 250mA negative pulse when remote start is activated and when the 

system’s alarm is disarmed� It can be programmed for 5th channel output with installer feature #9�

CONNECTION:

 Connect this wire to the vehicle’s OEM alarm disarm circuit� Typically, it will show 

ground when the door cylinder key is turned to the unlock position�

LT� GREEN/BLACK WIRE - OEM ALARM DISARM / CH5 (-) OUTPUT

 

This output provides a 250mA negative pulse when remote start is turned off and when the 

system’s alarm is armed� It can be programmed for 4th channel output with installer feature #9�

CONNECTION:

 Connect this wire to the vehicle’s OEM alarm arm circuit� Typically, it will show 

ground when the door cylinder key is turned to the lock position�

3 Pin Satellite Relay Port (RED)

GREEN WIRE - START (-) OUTPUT

 

This output provides a 250mA negative pulse when the large VIOLET start wire is active�

CONNECTION:

 If a negative starter circuit is needed, connect this directly to the vehicle’s nega-

tive starter circuit� Otherwise, use a relay (or RS-RP module) to convert this to a high current 

circuit�

BLUE WIRE - IGNITION (-) OUTPUT

 

This provides a 250mA negative output when the large PINK ignition wire is active�

CONNECTION:

 If a negative ignition circuit is needed, connect this directly to the vehicle’s nega-

tive starter circuit� Otherwise, use a relay (or RS-RP module) to convert this to a high current 

circuit�

RED WIRE - CONSTANT (+) OUTPUT

 

This output provides a 500mA positive output to drive the positive pin of added relay coils�

Summary of Contents for AL-XX50-EDPB

Page 1: ...AL XX50 EDPB Deluxe Keyless Entry Security Remote Start System Installation Guide May 21 2013 Temporary cover Color cover is in a separate file ...

Page 2: ... 6 Black Red Wire Light Relay N O Input 6 Green Violet Wire Light Relay COM Output 6 White Red Wire Light Relay N C Input 6 Violet Black Wire Horn Relay N O Input 6 Blue Black Wire Horn Relay COM Output 6 Brown Black Wire Horn Relay N C Input 6 6 Pin Secondary Wire Harness 7 Pink Wire 3rd Channel Output 7 White Blue Wire Remote Start Activation Input 7 White Wire Alarm Arm Input 7 Brown Wire Alarm...

Page 3: ...s in mind when deciding which ignition accessory circuits to power Most if not all will be required REQUIRED These wires provide the constant positive 12v power supply for the system s operation CONNECTION Connect these to a constant 12 volt supply with sufficient amperage for remote starting The 12v power supply to the ignition switch is ideal Some vehicle s have low amperage ignition switches in...

Page 4: ...m Ground Input REQUIRED This input provides negative ground for all system operations CONNECTION Using a properly sized ring terminal connect this wire to the vehicle s chassis Using an existing bolt is preferred but make sure that the connection point is clean and free of dirt grease or paint Bright shiny metal at the connection point is desired Orange Wire Starter Interrupt Output Relay This pro...

Page 5: ... 250mA negative output to flash the vehicle s parking lights typically If the vehicle has a positive parking light circuit use the WHITE wire instead CONNECTION Connect this wire to the vehicle s negative parking light circuit It will show ground when the parking lights are on BE SURE NOT TO CONNECT TO THE DIMMER CIRCUIT WHICH WILL CHANGE RESISTANCE TO GROUND AS YOU TURN THE DIMMER KNOB Gray Wire ...

Page 6: ... Input This circuit provides the input for the built in 10 amp domelight relay Specifically the normally closed pin pin 87a which is typically only used for polarity reversing circuits This relay can be programmed via installer feature 2 for LOCK IGNITION or ACCESSORY if need be CONNECTION Connect this wire to constant power or chassis ground as needed for the chosen function Violet Black Wire Hor...

Page 7: ... start is activated and when the system s alarm is disarmed It can be programmed for 5th channel output with installer feature 9 CONNECTION Connect this wire to the vehicle s OEM alarm disarm circuit Typically it will show ground when the door cylinder key is turned to the unlock position Lt Green Black Wire OEM Alarm Disarm CH5 Output This output provides a 250mA negative pulse when remote start ...

Page 8: ...Output WHITE Siren Output BROWN Horn Relay N C Input BROWN BLACK Horn Relay COM Output BLUE BLACK Horn Relay N O Input VIOLET BLACK 6 PIN POWE Constant 12v Input Ignition 2 Output Constant 12v Start Outp Ignition 1 Input Ou Accessory Outpu 10 AMP 3rd Chan Remote Start Activation Arm Ala Disarm Alar OEM Alarm Arm CH4 Outp OEM Alarm Disarm CH5 Output BL Harness BLADE Programming interafce Module Dat...

Page 9: ...OCK PORT Unlock 2 Output PINK Unlock 1 Output BLUE Constant 12v Output RED Lock Output GREEN 3 PIN SAT RELAY PORT BLUE Accessory Output GREEN Constant 12v Output RED Status Output BLUE 3 PIN SAT RELAY PORT RED Start Output GREEN Constant 12v Output RED Ignition Output BLUE BLADE Harness Port nterafce Module Data Port nterface Module Data Port Antenna Status Light Valet Switch Backup Battery Port S...

Page 10: ...s The pulse tim ing is programmable by installer feature 1 CONNECTION Connect this directly to the vehicle s all door unlock circuit if a negative pulse is required Otherwise a doorlock interface and or relays are required to convert the output If you are configuring the system for driver s priority unlocking connect this only to the driver s door unlock circuit Pink Wire Unlock 2 Output This prov...

Page 11: ...ware for any BLADE cartridge used in lieu of a standard interface module When connected to the OmegaLink OL LOADER this port can also be used to configure all programmable features as well as update the entire system s firmware These functions may require a BLADE cartridge to be installed When utilizing an OmegaLink BLADE module this 20 pin connector is used for the harness that is included with t...

Page 12: ...n on to indicate it has learned the current tach signal If it does not light check your tach connection and start this procedure again Step 4 If the engine has a high idle at startup it may be necessary to allow the idle to settle to around 700 RPM If needed you can press the valet switch 1 time to resample the tach signal The status light will flash off then back on once the signal has been resam...

Page 13: ...is ready to learn a transmitter controller code To enter a code simply press and release the lock button When the first code is learned all existing stored codes will be erased Special Programming procedure to turn On the UTA feature Using this method to program transmitters or optional controllers and to turn on the Unauthorized Transmitter Alert feature Follow the same steps as the Standard Prog...

Page 14: ...pressing the brake The siren horn will chirp equal to the selected setting Step 5 If you wish to change more features repeat steps 3 4 at this time Step 6 To exit programming turn the ignition key ON then OFF Or it will exit automatically after 10 seconds of no activity This device complies with FCC Rules part 15 Operation is subject to the fol lowing two conditions 1 This device may not cause har...

Page 15: ...e Start Activation Start Pulse x 2 Start Pulse x 1 Lock Unlock 18 Remote Start Run Time 5 min 10 min 15 min 20 min Installer Feature Programming Ignition on off press valet 10 times 1 Doorlock pulse 0 8 sec 3 sec Double unlock Total closure 2 Light Relay Functions Dome light Lock Ignition Acc 3 Horn Relay Functions Horn Unlock Trunk Release Pulse after Start 4 Turbo Timer Off 1 min 2 min 3 min 5 M...

Page 16: ...Temporary back cover Color cover is in a separate file IM_AL XX50 EDPB v2_5 21 2013 ...

Reviews: