Chapter 2
Channel Operation
page 2 - 14
Excalibur Systems
Write/
Read
In continuous modes the Transmit Interval Value Register sets the interval time
between the start of each of the contiguous 708 words.
2.3.15
Transmit Interval Value Register
Address:
xx04A (H)
Bit
Bit Name
Description
00-15
Intrvl_Val
Interval Value
Resolution = 0.1msec/bit.
Minimum interval time = 1.6msec [0010 H value in register] for
no gap between words
Maximum interval time
≅
6.5 sec.[FFFF H]
Set to 0037 (H) upon power-up or reset for a default value of
5.5 msec
Transmit Interval Value Register
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com