Wiring Overview

6 PIN POWER HARNESS

Accessory (+) Output  -  ORANGE

Ignition #1 (+) Input/Output  -  PINK

Start (+) Output  -  VIOLET

Constant 12v (+) Input  -  RED

Ignition #2 (+) Output  -  PINK/WHITE

Constant 12v (+) Input  -  RED/WHITE

30 AMP

30 AMP

3 PIN SAT� RELAY PORT (RED)

Start (-) Programmable Output  -  GREEN

Constant 12v (+) Output  -  RED

Status (-) Programmable Output  -  BLUE

Green

Data 

Port

Summary of Contents for RS-340-EDPplus

Page 1: ...RS 340 EDP RS 450 EDP Deluxe Keyless Entry Remote Start Installation Guide July 11 2012 Temporary cover Color cover is in a separate file...

Page 2: ...tput 8 White Blue Wire Remote Start Activation Input 8 Lt Green Red Wire OEM Alarm Arm Output 8 Lt Green Black Wire OEM Alarm Disarm Output 8 Red White Wire Trunk Release CH2 Output 8 Green Black Data...

Page 3: ...his in mind when deciding which ignition accessory circuits to power Most if not all will be required REQUIRED These wires provide the constant positive 12v power supply for the system s operation CON...

Page 4: ...s negative ground for all system operations CONNECTION Using a properly sized ring terminal connect this wire to the ve hicle s chassis Using an existing bolt is preferred but make sure that the conne...

Page 5: ...operate the vehicle s horn CONNECTION Connect this wire to the vehicle s horn circuit If the vehicle s circuit is something other than negative you will need to use a relay to convert this output Whit...

Page 6: ...REEN RED Trunk Release CH2 Output RED WHITE System Ground Input BLACK OEM Alarm Disarm Output GREEN BLACK Horn Output BROWN Hood Trigger Input GRAY Brake Input BROWN RED Tach Input VIOLET WHITE Flashi...

Page 7: ...put Output PINK Start Output VIOLET Constant 12v Input RED Ignition 2 Output PINK WHITE Constant 12v Input RED WHITE 30 AMP 30 AMP 3 PIN SAT RELAY PORT RED Start Programmable Output GREEN Constant 12v...

Page 8: ...tput provides a 250mA negative pulse when remote start is turned off and when the system s alarm is armed CONNECTION Connect this wire to the vehicle s OEM alarm arm circuit Typically it will show gro...

Page 9: ...ides a 0 8 second 250mA negative pulse for any locking operations The pulse timing is programmable by installer feature 9 CONNECTION Connect this directly to the vehicle s lock circuit if a negative p...

Page 10: ...ch wire connection perform the following steps Step 1 Turn the ignition key ON Step 2 Within 5 seconds press the brake pedal 5 times the siren will chirp 5 times Step 3 Start the engine The status lig...

Page 11: ...es Feature programming can also be performed via the OL LOADER using www omegaweblink com User Feature Programming Ignition on off press valet 5 times Feature Lock Button Unlock button Trunk button ST...

Page 12: ...Back Cover Color cover is in a separate file...