Programmable Features Matrix
This device complies with FCC Rules part 15. Operation is subject to the following two condi-
tions, (1) This device may not cause harmful interference and, (2) This device must accept
any interference that may be received, including interference that may cause undesired
operation.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user’s authority to operate
the equipment.
Feature #12 Data Port Protocol
D2D (Trilogix)
(press “
lock
” button to program)
- DEFAULT
ADS (iData)
(press “
unlock
” button to program)
This feature determines which data protocol is used on the data port. Choose this
based on the interface module protocol being used.
NOTE: Intellikit modules only
support the D2D protocol. All OmegaLink modules support BOTH protocols
however, the ADS protocol is recommended for maximum capabilities.
User Feature Programming: Ignition on, off, press valet 5 times
# Feature
Lock Button Unlock button
Trunk button
”START” button
1 Engine Run Time
10 min
5 min
15 min
20 min
2 Steady/Flashing lights for RS Steady
Flashing
3 Horn Honk Volume
Low
Hi
On Demand
OFF
4 Pulse Horn/Steady Siren
Pulsed Lo
Pulsed Med
Pulse Hi
Steady Siren
5 Doors Lock w/ Ign. ON
ON
OFF
6 Doors Unlock w/ Ign. OFF
ON
OFF
7 Unlock w/ Trunk Release
ON
OFF
Installer Feature Programming: Ignition on, off, press valet 10 times
1 RS Activation
1 press
2 presses
3 presses
4 presses
2 PINK/WHITE wire function
Ignition
Accessory
Start
3 Engine Detection
Tachless Hi
Tachless Lo
Tach Wire
Datatach
Crank Only (Press Lock +Unlock)
4 Gas or Diesel Engine
Gas
Diesel
(15 sec delay)
Diesel
(20 sec delay)
Diesel
(30 sec delay)
5 Sat. Port Green Wire
Starter
Pulse After Start Status
Domelight
6 Sat. Port Blue Wire
Status
Ignition
7 Crank Time
0.7 Sec
1.00 Sec
1.5 Sec
2.25 Sec
8 Doorlock Outputs
0.8 Sec
3 sec
Double Unlock
Total Closure
9 Remote Start Lock Control
Off
Lock After Start Unlock Before
Start
Both
10 Turbo Timer
OFF
1 min
2 min
3 min
11 Manual Transmission RS
ON
OFF
12 Data Port Protocol
D2D (Trilogix) ADS (iData)