26
INSTALLATION
excel HE -
Installation and Servicing
33 ELECTRICAL CONNECTIONS
For Ireland reference should be made to the current ETCI
rules for electrical installations.
The supply connection is intended to be made via a double
pole switch having a 3mm (1/8") contact separation in both
poles, serving only the boiler and system controls.
The fuse rating should be 3A.
WARNING
.
This appliance MUST be earthed
.
A mains supply of 230 V ~ 50 Hz is required.
Mains wiring should be 3 core PVC insulated flexible cord
NOT LESS than 0.75mm
2
(24x0.2mm) and to BS. 6500, Table
16. (0.5mm
2
flex is not acceptable - for mechanical, not
electrical reasons.)
Mains wiring external to the boiler MUST be in accordance
with the current I.E.E. (BS7671) Wiring Regulations and any
local regulations.
34 INTERNAL WIRING
INCOMING MAINS WIRING DETAIL
To gain access to the power supply and external controls
terminal block:
1.
Remove the screws and the cover panel.
2.
Remove the control box fixing screws.
3.
Pull the control panel forward.
4.
Remove the screws and the service panel.
M
ains
ix7421
L
N
F1
F2
Lin
k
R1
R2
R3
LEGEND
L
Live
N
Neutral
Earth
F1
Frost Stat Switched Live
F2
Frost Live Feed
R1 Room Stat Switched Live
R2 Room Live Feed
R3 Programmer Common SWL
Note.
Ensure that the lengths of the current conductors are shorter than the earth conductor so that if the cable slips in its
anchorage the current carrying conductors become taut before the earth conductor.
Service
panel
ex7787
3
4
ix7424
1
2
I
N
ST
A
L
L
A
T
I
O
N