45
SERVICING
excel HE -
Installation and Servicing
72 CH THERMISTOR AND DHW THERMISTOR
1.
Refer to Frame 51.
2.
Remove the boiler front, side and sealing
panels. Refer to Frame 44 and 45. Put the
control box into the servicing position.
Refer to Frame 46.
3.
Drain the boiler water circuits. Refer to
Frame 67.
4.
To remove the CH thermistor (red wires)
pull out the "U" shaped retaining clip.
5.
To remove the DHW thermistor (blue wires)
pull out the "U" shaped retaining clip.
6.
Fit new thermistor and retain with "U"
shaped clip.
7.
Re-assemble in reverse order.
8.
Refill the boiler. Refer to Frame 32.
9.
Check the operation of the boiler. Refer to
Frame 50 and 51.
73 DIVERTER VALVE MECHANISM REPLACEMENT
1.
Refer to Frame 51.
2.
Remove the boiler front, side and sealing
panels. Refer to Frame 44 and 45. Put the
control box into the servicing position. Refer
to Frame 46.
3.
Drain the boiler water circuits. Refer to
Frame 67.
4.
To remove the diverter valve mechanism,
pull out the "U" shaped retaining clip.
5.
Fit new diverter valve mechanism and retain
with "U" shaped clip.
6.
Re-assemble in reverse order.
7.
Refill the boiler. Refer to Frame 32.
8.
Check the operation of the boiler. Refer to
Frame 50 and 51.
SER
VI
C
I
N
G
4
5
4