46
Protective Limits
Parameter
Description
Module
Min
Nom /
Typical
Max
Current Limit (A)
Constant Current Limit into Hiccup.
Auto-Recovery
Co
o
lX600
CmA
23.1
25.2
27.3
CmB
16.5
18.1
19.5
CmC
9.2
9.7
10.8
CmD
4.6
4.9
5.4
Co
o
lX1800
CmA
40.7
44.4
48.1
CmB
27.5
30
32.5
CmC
13.8
15
16.2
CmD
6.9
7.5
8.1
Short-Circuit
Current Limit (A)
Measured over 5 hiccup cycles
Co
o
lX600
CmA
4.2
CmB
3
CmC
1.7
CmD
0.9
Co
o
lX1800
CmA
6
CmB
4.7
CmC
2.5
CmD
1.25
Power Limit (W)
Voltage Foldback into Hiccup, Auto-Recovery
CmA
115
130
137
CmB
198
220
234
CmC
220
230
260
CmD
220
230
260
Overvoltage
Protection (V)
CoolX600: Shutdown, Latch-off
CoolX1800: Shutdown, Auto-Recovery
CmA
6.8
8
9
CmB
17
19.8
21
CmC
32
35
37
CmD
60
62.2
66
Sense Lead
Protection (V)
Shutdown, Auto-Recovery
All Mods
3.1
Start-Up / Shut-Down
Parameter
Description
Module
Min
Nom /
Typical
Max
Turn-On Delay (ms)
Time from Application of Input AC to Output
Voltage Regulation (t1)
All Mods
640
800
Turn-Off Delay (ms)
From Loss of AC to Loss of Output Voltage
Regulation
–
Nominal Voltage (t2)
All Mods
16
20
Summary of Contents for CoolX1800