SSE232-IA3 – Serial Server- User’s Manual
Exemys
www.exemys.com
Rev.4
14
3.4
3.4
3.4
3.4
Common
Common
Common
Common parameters
parameters
parameters
parameters
3.4.1
3.4.1
3.4.1
3.4.1
Serial Port Configuration
Serial Port Configuration
Serial Port Configuration
Serial Port Configuration
The following parameters can be configured in the device serial port:
Par
Par
Par
Parameter
ameter
ameter
ameter
Op
Op
Op
Options
tions
tions
tions
Configuration
Manual / Automatic
Com Port Type
RS-232 / RS-485
Baud Rate
300 to 115200 bps
Data Bits
7 / 8
Parity
No / Even / Odd
Stop Bits
1 / 2
Flow Control
(only RS-232)
Enabled/Disabled
Automatic port parameters configuration is available since firmware version 3.8.
This feature will accept automatic Baud Rate, Data bits, Parity and Stop bits from a Serial Port redirector
that supports Telnet – RFC2217 (For example Serial/IP).