Fault Location Tests
98
AXS-200/635
Loop Mapper Test
Loop Mapper Test
The LoopMapper test allows you to easily identify faults in the cable with
increased resolution using time domain reflectometry (TDR) and
frequency domain reflectometry (FDR). This test is extremely useful in
locating bridge taps and the end of the cable. Faults such as open ends and
shorted ends can be easily found using the enhanced resolution of the FDR
test.
Note:
This test is only available if LoopMapper is enabled in the software options.
Test Setup
The
Test Setup
tab allows you to configure parameters for the Loop
Mapper test.
Define the
Cable Type
by selecting the
gauge of the cable in use. If wire gauge
is measured in AWG units, the
available choices are:
AUTO
,
19 AWG
,
22 AWG
,
24 AWG
, or
26 AWG.
For mm
gauge wire, the available choices are:
AUTO
,
0.32 mm
,
0.40 mm
,
0.50 mm
,
0.60 mm
,
0.65 mm
,
0.80 mm
,
0.90 mm
, or
1.20 mm
.
To set parameter values and start/stop the test:
1.
Press
to display the list.
2.
Use the up/down arrow key to highlight the desired value, and press
to accept the value.
3.
Press
to start/stop the test.