Auto CQ/Video-DSL Rate Prediction
30
AXS-200/635
Configuring CQ Auto Tests
VF Test Parameters
The
VF Parameters
tab allows you to
set up parameters used in the voice
frequency tests.
Each parameter is described below:
³
VF Noise Filter
defines the level of
voice frequency noise filtering. If
the ANSI standard is used, the
available choices are:
NONE
,
C-MESSAGE
,
C NOTCHED
,
3 kHz FLAT
,
D-FILTER
or
15 kHz
. If the ITU standard is used, the
available choices are:
NONE
,
PSOPHOMETRIC
,
P-NOTCHED
,
3 kHz FLAT
,
D-FILTER
or
15 kHz
.
³
VF Termination
defines if the unit uses normal test impedance
termination or high bridging impedance when the cable is active or
terminated by other external equipment. For normal test termination
select
TERMINATED
, otherwise select
BRIDGING
.
³
Imp. Noise Filter
defines the type of impulse noise filtering to use. If
ANSI standard is used, the available choices are:
NONE
,
C-MESSAGE
,
C NOTCHED
,
3 kHz FLAT
,
D-FILTER
or
15 kHz
. For the ITU standard,
the choices are:
NONE
,
PSOPHOMETRIC
,
P-NOTCHED
,
3 kHz FLAT
,
D-FILTER
or
15 kHz
.
³
Low Threshold(dBm)
defines the low threshold limits for impulse
noise. Specify a value between -
40
and
0
.
³
Separation(dB)
defines the level difference (in dB) between the low,
the mid and high thresholds. Specify a value between
1
and
6
dB.
³
Imp. Noise Measure. Time
defines the time duration to measure
impulse noise. The available choices are:
1 minute
,
5 minutes
,
10 minutes
,
15 minutes
,
60 minutes
, or
24 hours
.