Auto CQ/Video-DSL Rate Prediction
34
AXS-200/635
Configuring CQ Auto Tests
Thresholds 1
The
Thresholds 1
tab allows you to set
threshold values for the auto tests.
Each parameter is described below:
³
Max. AC Voltage T-R (V)
defines
the maximum AC threshold
voltage for the T-R leg of the circuit.
Specify a value between
1
and
30
.
³
Max. AC Voltage to GND (V)
defines the maximum AC threshold voltage to ground for the circuit.
Specify a value between
1
and
30
.
³
Max. DC Voltage T-R (V)
defines the maximum DC threshold voltage
for the T-R leg of the circuit. Specify a value between
1
and
400
.
³
Max. DC Voltage to GND (V)
defines the maximum DC threshold
voltage to ground for the circuit. Specify a value between
1
and
400
.
³
Min. Resistance T-R(MOhm)
: defines the minimum threshold
resistance for the T-R leg of the circuit. Specify a value between
0
and
999
.
³
Min. Resistance T-G(MOhm)
defines the minimum threshold
resistance for the T-G leg of the circuit. Specify a value between
0
and
999
.
³
Min. Resistance R-G(MOhm)
defines the minimum threshold
resistance for the R-G leg of the circuit. Specify a value between
0
and
999
.