DMM Tests
74
AXS-200/635
In Service Pair Detection Test
In Service Pair Detection Test
At the start of the In Service Pair Detection test, the unit will check for the
presence of dangerous voltage and an active circuit. If dangerous voltage is
detected, a dialog box will be displayed to inform you and the test will stop.
If an active circuit is detected, a dialog box will be displayed to ask the you
whether or not to proceed with the test.
In Service
The
In Service Pair Detection Test
uses the black and green (ground)
leads to quickly check if wire pairs are
in service
or available for usage. This
test checks for the following:
³
dangerous voltages
³
high voltages
³
POTS battery (>45 V)
³
digital service signals
³
a bad ground connection
Note:
Test beeps or warns when ground is NOT present or very poor.