VF / DSL Cable Qualifier
194
For only resistive faults, the CableSHARK’s RFL test will instruct the user how to attach the strap (
see
Section 12.1.1.6
) at the far end.
WARNING
Fault found between RING and GROUND.
Connect a good pair to Yellow and Blue.
Connect far end strap from wire connected to Red
to both ends of good pair.
!
F
IGURE
12.1.1.5D
–
RFL
M
ESSAGE INDICATING PLACEMENT OF
S
TRAP
#2
At the conclusion of the RFL Isolation test, a WARNING box will appear indicating where the fault is (i.e. T-
R, R-G, T-G, not distance) and how to connect the strap (
see Section 12.1.1.6
) at the far end. Once the
strap is hooked up, the user can press the CONTINUE button to advance to the RFL SETUP menu.
NOTE: The user should locate a good pair before actually proceeding to the RFL SETUP menu.
12.1.1.6 Connecting the Strap
A strap is typically a wire that connects the ends of a good pair to a wire on the faulty pair. The strap should
be made of 18AWG (1.0 mm) and be very short because it will have a very low resistance and will not affect
the measurement. Alternatively, the same gauge of cable can be used but again must be very short as to not
adversely affect the measurement.
Here are the possible hook-ups that can be done, depending upon the fault (others can exist).
Fault TIP-RING
T
R
T
R
Good pair
Strap
Faulty pair
GURE
12.1.1.6A
–
T
IP
-R
ING
F
AULT
:
S
TRAP
P
LACEMENT
Summary of Contents for CableSHARK P3
Page 1: ......
Page 10: ...VF DSL Cable Qualifier viii...
Page 12: ...VF DSL Cable Qualifier x...
Page 26: ...VF DSL Cable Qualifier 14...
Page 36: ...VF DSL Cable Qualifier 24...
Page 64: ...VF DSL Cable Qualifier 52...
Page 80: ...VF DSL Cable Qualifier 68...
Page 184: ...VF DSL Cable Qualifier 172...
Page 192: ...VF DSL Cable Qualifier 180...
Page 224: ...VF DSL Cable Qualifier 212...
Page 228: ...VF DSL Cable Qualifier 216...
Page 262: ...VF DSL Cable Qualifier 250 CSA Loop 6 CSA Loop 7 CSA Loop 8 Extended CSA Loop 9...
Page 263: ...CableSHARK P3 User Guide 251 Extended CSA Loop 10 Mid CSA Loop 0 Mid CSA Loop 1 Mid CSA Loop 2...
Page 264: ...VF DSL Cable Qualifier 252 Mid CSA Loop 3 Mid CSA Loop 4 Mid CSA Loop 5 Mid CSA Loop 6...
Page 265: ...CableSHARK P3 User Guide 253 ANSI Loop 2 ANSI Loop 3 ANSI Loop 4 ANSI Loop 5...
Page 266: ...VF DSL Cable Qualifier 254 ANSI Loop 6 ANSI Loop 7 ANSI Loop 8 ANSI Loop 9...
Page 267: ...CableSHARK P3 User Guide 255 ANSI Loop 11 ANSI Loop 12 ANSI Loop 13 ANSI Loop 15...
Page 268: ...VF DSL Cable Qualifier 256...
Page 286: ...VF DSL Cable Qualifier 274...
Page 292: ...VF DSL Cable Qualifier 280...
Page 294: ...VF DSL Cable Qualifier 282...
Page 316: ...VF DSL Cable Qualifier 304...
Page 318: ...VF DSL Cable Qualifier 306...
Page 319: ...CableSHARK P3 User Guide 307 Notes...
Page 320: ...VF DSL Cable Qualifier 308...