CableSHARK
P3
User Guide
197
American Wire Gauge.
RESISTENCE
PER LENGTH
Allows the user to specify the cable’s resistance constant. See Appendix B for more
information on loop characteristics.
NOTE: When the Cable Type or Temperature changes, this value will automatically
change to reflect a new cable type or a lower or higher temperature. The initial setting
is based on nominal room temperature (68°F or 20°C).
DISTANCE
Allows the user to specify the cable section length under test. This is one gauge of
wire only.
NOTE: If DISTANCE is entered, the TEMPERATURE setting will be ignored. To
enter an unknown distance, input the # sign.
TEMPERATURE
Allows the user to specify the temperature of the cable section under test.
NOTE: If TEMPERATURE is entered, the DISTANCE setting must be set to #.
NOTE: To enter negative temperatures, highlight the Temperature Edit box, press
the EDIT/SELECT button to change the temperature and press the * (asterisk)
key twice to enter the negative sign. Press the RIGHT ARROW key to advance to
the next character position and start to enter the numerical temperature.
LOAD COIL
Allows the user to specify whether the section under test contains load coils. Load
coils will add approximately 150 feet or 45 meters to the measurement for each load
coil (based on 88 mH load coils).
Press the EDIT/SELECT button to change a setting or enter a new value. Use the LEFT/RIGHT ARROW
keys to navigate to the different settings.
12.1.1.8 Setup the RFL Test for Multi-Section Testing
Users can enter loop characteristics for multi-section loops into the CableSHARK by pressing the MULTI-
SECTION key. Users can enter characteristics of up to 5 sections into the CableSHARK. Typically a section
is a different gauge of wire.
Summary of Contents for CableSHARK P3
Page 1: ......
Page 10: ...VF DSL Cable Qualifier viii...
Page 12: ...VF DSL Cable Qualifier x...
Page 26: ...VF DSL Cable Qualifier 14...
Page 36: ...VF DSL Cable Qualifier 24...
Page 64: ...VF DSL Cable Qualifier 52...
Page 80: ...VF DSL Cable Qualifier 68...
Page 184: ...VF DSL Cable Qualifier 172...
Page 192: ...VF DSL Cable Qualifier 180...
Page 224: ...VF DSL Cable Qualifier 212...
Page 228: ...VF DSL Cable Qualifier 216...
Page 262: ...VF DSL Cable Qualifier 250 CSA Loop 6 CSA Loop 7 CSA Loop 8 Extended CSA Loop 9...
Page 263: ...CableSHARK P3 User Guide 251 Extended CSA Loop 10 Mid CSA Loop 0 Mid CSA Loop 1 Mid CSA Loop 2...
Page 264: ...VF DSL Cable Qualifier 252 Mid CSA Loop 3 Mid CSA Loop 4 Mid CSA Loop 5 Mid CSA Loop 6...
Page 265: ...CableSHARK P3 User Guide 253 ANSI Loop 2 ANSI Loop 3 ANSI Loop 4 ANSI Loop 5...
Page 266: ...VF DSL Cable Qualifier 254 ANSI Loop 6 ANSI Loop 7 ANSI Loop 8 ANSI Loop 9...
Page 267: ...CableSHARK P3 User Guide 255 ANSI Loop 11 ANSI Loop 12 ANSI Loop 13 ANSI Loop 15...
Page 268: ...VF DSL Cable Qualifier 256...
Page 286: ...VF DSL Cable Qualifier 274...
Page 292: ...VF DSL Cable Qualifier 280...
Page 294: ...VF DSL Cable Qualifier 282...
Page 316: ...VF DSL Cable Qualifier 304...
Page 318: ...VF DSL Cable Qualifier 306...
Page 319: ...CableSHARK P3 User Guide 307 Notes...
Page 320: ...VF DSL Cable Qualifier 308...