Figure 7.16A – VF Auto Test Results
7.17 Ground Resistance Test
Note: This is a Single-ended test.
The CableSHARK’s Ground Resistance (also known as Station Ground) test allows technicians to verify that
correct grounding rules are being followed at the location under test. An adequate station ground and
ground distribution system provides a common electrical reference point for all telecommunications
equipment in the installation and minimizes the danger of electrical potential between various equipments
and between equipments and the earth.
1. From the Main Menu, select CABLE TESTS (function button F1).
2. Choose GROUND RESISTANCE from the pop-up menu. Ensure the RING connection of the
CableSHARK is connected to the lead on the negative side of the CO battery, the TIP connection
connected to the lead on the positive side of the CO battery and the GROUND connection to ground at
the CO.
3. Press the RUN / STOP button to start the test. Depending upon the CO line card properties and
whether it is active or not, the Ground Resistance measurement will give the user the station voltage,
the loop current, the loop impedance and the ground resistance. Resistance values of less than 25
ohms are considered acceptable. Anything over 25 ohms means there is a ground resistance problem.
To repeat the test, press the RUN/STOP button.
Summary of Contents for CableSHARK P3
Page 1: ......
Page 10: ...VF DSL Cable Qualifier viii...
Page 12: ...VF DSL Cable Qualifier x...
Page 26: ...VF DSL Cable Qualifier 14...
Page 36: ...VF DSL Cable Qualifier 24...
Page 64: ...VF DSL Cable Qualifier 52...
Page 80: ...VF DSL Cable Qualifier 68...
Page 184: ...VF DSL Cable Qualifier 172...
Page 192: ...VF DSL Cable Qualifier 180...
Page 224: ...VF DSL Cable Qualifier 212...
Page 228: ...VF DSL Cable Qualifier 216...
Page 262: ...VF DSL Cable Qualifier 250 CSA Loop 6 CSA Loop 7 CSA Loop 8 Extended CSA Loop 9...
Page 263: ...CableSHARK P3 User Guide 251 Extended CSA Loop 10 Mid CSA Loop 0 Mid CSA Loop 1 Mid CSA Loop 2...
Page 264: ...VF DSL Cable Qualifier 252 Mid CSA Loop 3 Mid CSA Loop 4 Mid CSA Loop 5 Mid CSA Loop 6...
Page 265: ...CableSHARK P3 User Guide 253 ANSI Loop 2 ANSI Loop 3 ANSI Loop 4 ANSI Loop 5...
Page 266: ...VF DSL Cable Qualifier 254 ANSI Loop 6 ANSI Loop 7 ANSI Loop 8 ANSI Loop 9...
Page 267: ...CableSHARK P3 User Guide 255 ANSI Loop 11 ANSI Loop 12 ANSI Loop 13 ANSI Loop 15...
Page 268: ...VF DSL Cable Qualifier 256...
Page 286: ...VF DSL Cable Qualifier 274...
Page 292: ...VF DSL Cable Qualifier 280...
Page 294: ...VF DSL Cable Qualifier 282...
Page 316: ...VF DSL Cable Qualifier 304...
Page 318: ...VF DSL Cable Qualifier 306...
Page 319: ...CableSHARK P3 User Guide 307 Notes...
Page 320: ...VF DSL Cable Qualifier 308...