Multimeter Tests
150
FTB-610
Capacitance/Opens Test
Capacitance/Opens Test
The
Opens
test measures the capacitance of the loop and calculates
length. Capacitive balance is also measured when all pairs are selected.
Snapshot
The capacitance/opens
Snapshot
shows measured
Capacitance
values
and
Length
for each lead combination. The page also displays a snapshot
of the pass/fail status,
Capacitance
and
Length
for each selected wire pair.
Capacitive Balance
is shown in
%
when
All Pairs
is selected.
To access Snapshot page:
1.
From the
Copper
main menu
Test Groups
, select
Multimeter
test
.
2.
From the
Tests
menu, select
Opens
test to start the test.
By default, the
Snapshot
page opens.
The current group and the current test which is being measured is
displayed in the status bar, for example
Multimeter\Opens
.