Technical Specifications
Copper Test
309
COPPER SPECIFICATIONS
a, b, c
(continued)
Load coil detection
Count
Up to 5
Plot
Up to 10 kHz
Distance range
Up to 8000 m (up to 27 000 ft)
Near End Crosstalk (NEXT)
Frequency Range
10 kHz to 30 MHz
Level Range
0 to 90 dB
Level Resolution
0.1 dB
Level uncertainty (accuracy)
2.2 MHz: ±2.0 dB, from 0 to 90 dB
8 MHz: ±2.0 dB, from 0 to 85 dB
12 MHz: ±2.0 dB, from 0 to 80 dB
17.6 MHz: ±3.0 dB, from 0 to 80 dB
30 MHz: ±3.0 dB, from 0 to 80 dB
Terminations
100, 120, 135, 150
1
Power spectral density (PSD)
Test type
Continuous with peak-hold, disturber identification, spectral mask overlay,
and bridging impedance features
Vertical scale
15 dBm/Hz to –140 dBm/Hz or 20 dBm to –100 dBm
Horizontal scale
4.3125 kHz to 17 MHz, in 4.3125 kHz steps or
8.625 kHz to 30 MHz, in 8.625 kHz steps
Noise filters
None or E, F, G, ADSL, ADSL2+, VDSL, VDSL2-8, VDSL2-12, VDSL2-17 and VDSL2-30
Wideband impulse noise
Test type
Counter, count histogram, time and frequency scope, duration and disruption histogram (IDD)
Counter, count histogram threshold
–60 dBm (30 dBrn) to 0 dBm (90 dBrn) in 1 dB steps
Scope threshold
0.000 V to 7.000 V in 0.001 increments
(0 V provides continuous triggering)
IDD threshold
–60 dBm to 15 dBm
Total impulse hit count
65 000 000
Total impulse disruption time
65 000 000 ms
Range
Scope: 10 μs to 10 ms
IDD: 1 μs to 20 ms
Test duration
Counter, histogram – minutes: 1, 5, 10, 15, 30 and 60
Counter, histogram – hours: 4, 8, 12, 24 and 100
Scope: continuous and capture/trigger modes
Impulse separation time (IST)
1 μs to 999 μs
Noise filters
None or E, F, G, ADSL, ADSL2+, VDSL, VDSL2-8, VDSL2-12, VDSL2-17 and VDSL2-30
Wideband longitudinal balance
Level scale
0 to 100 dB
Level range uncertainty (accuracy)
2.2 MHz: ±2.0 dB, from 0 to 55 dB
8 MHz: ±2.0 dB, from 0 to 45 dB
12 MHz: ±3.0 dB, from 0 to 45 dB
17.6 MHz: ±3.0 dB, from 0 to 40 dB
30 MHz: ±4.0 dB, from 0 to 40 dB
Level resolution
0.1 dB
Frequency resolution
1 kHz
Frequency uncertainty (accuracy)
±(50 ppm + 1 digit)
Frequency scale
ADSL/2+: 10 kHz to 2.2 MHz
VDSL2-8 : 20 kHz to 8 MHz
VDSL2-12: 20 kHz to 12 MHz
VDSL2-17: 35 kHz to 17.6 MHz
VDSL2-30: 35 kHz to 30 MHz
Fault location
Total resistance, near-end to fault resistance, fault to strap resistance (three significant
digits, least significant digit 0.1
1
).
Total length, distance to fault, distance from fault to strap
(three significant digits, least significant digit 1 m)
Uncertainty (accuracy)
±(0.1
1
+ 1 % x RTS)
NOTES
a. Subject to change without notice.
b. Typical, at 23 °C ± 3 °C, on batteries, with no USB connection.
c. Specifications based on 24 AWG (PE 0.5 mm) cabling.