SyncE Test Setup and Results
208
FTB-860/880
Summary (SyncE)
RX
Last QL Message
indicates the last Quality Level value received. The
pass/fail verdict is also displayed when both
QL Mismatch Monitoring
and
Pass/Fail Verdict
check boxes are selected.
Last Change
indicates the date and time of the Last QL Message has
changed.
Information/Event Count
gives respectively the count of information
and event frames generated for all Quality Level values.
QL Mismatch Frame Count
gives the total count of information and/or
event frames received not matching the expected Quality Level. Only
available when the
QL Mismatch Monitoring
check box is selected.
Frequency/Offset
indicates respectively the frequency and the offset
between the standard rate specification and the rate
of the input signal.
Max. (-/+) Offset (ppm)
indicates respectively the minium and
maximum offset between the standard rate specification and the
largest/smallest rate recorded from the received signal.
TX
QL Message
indicates the Quality Level value that is generated.
Last Change
indicates the date and time of the QL Message value has
changed. For 1GE Electrical interface using
Local Clock
set to
Slave
,
the
Last Change
is not available.
Information/Event Count
gives respectively the count of information
and event frames generated for all Quality Level values.
Event Count
is
not available with 1GE Electrical interface using remote local clock.
Summary of Contents for FTB-860
Page 7: ...NetBlazer vii B Glossary 371 Acronym List 371 VLAN 379 1588 PTP 380 SyncE 385...
Page 12: ......
Page 16: ......
Page 20: ......
Page 30: ......
Page 84: ......
Page 110: ......
Page 122: ......
Page 152: ......
Page 166: ......
Page 182: ......
Page 192: ......
Page 224: ......
Page 366: ......
Page 376: ......
Page 382: ...Specifications 370 FTB 860 880 Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...