EtherSAM Test Setup and Results
NetBlazer
57
Summary Results
Aborted – No remote connection
Aborted – Loss of remote connection:
This status will appear
only when the Dual Test Set Connection is lost during the DTS
EtherSAM test.
Start Time
: The time when the
EtherSAM
test was started.
Note:
While a subtest is in progress, the status and results are displayed on the
page in real time, and are retained under the results table for each subtest.
Service
: Displays the name of the service.
Max Throughput
: indicates the measured maximum utilization
throughput. It is only available for
Service Configuration Test
.
Avg. Throughput (Mbit/s)
: It specifies the average throughput. It is
only available for
Service Performance Test
.
% Frame Loss
: indicates the percentage of frame that are lost. The
reported value is the maximum percentage of Frame Loss from all the
ramp steps including the
Overshoot
step.
Max. Jitter (ms)
: indicates the maximum measured delay variation.
Round-trip Latency (ms)
: indicates the average measured round trip
latency (delay).
Service Verdict
: Indicates if the service complies (pass) or not (fail) to
the configured SLA parameters. Refer to
more details.
Summary of Contents for FTB-860
Page 7: ...NetBlazer vii B Glossary 371 Acronym List 371 VLAN 379 1588 PTP 380 SyncE 385...
Page 12: ......
Page 16: ......
Page 20: ......
Page 30: ......
Page 84: ......
Page 110: ......
Page 122: ......
Page 152: ......
Page 166: ......
Page 182: ......
Page 192: ......
Page 224: ......
Page 366: ......
Page 376: ......
Page 382: ...Specifications 370 FTB 860 880 Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...