Creating and Starting a Test Case
86
IQS-8500 Series and IQS-8120NGE/8130NGE
Ethernet EtherSAM (Y.1564) and RFC 2544 Dual Test Set Test Cases
1c.
From the
Remote Module
page, press the
Remote Selection
button.
1d.
If both modules (remote and local) are on the same subnet,
select the subnet mask (
Broadcast Destination
) of the network
to be scanned, based on the IP address and subnet of its
interface. Available with IPv4 only.
If the remote and local modules are not on the same subnet, like
when connected through a Router, enter the remote module IP
address in the
IP Address
field of the
Remote Module
Connection
section. For IPv6, entering a Global IPv6 destination
address requires that the interface
Global IPv6 Address
is
defined. The
Remote ID
and its
Status
are displayed if the module
is detected. Skip to step 1g.
IPv4
IPv6