Port Tabs
Ethernet and Fibre Channel Application
157
Advanced Auto-Neg. TX
Auto-Neg. Fault Register
Fault Type
: Allows the generation of a fault during the negotiation process.
Changing the fault type, while enabled, will automatically restart the
negotiation process. The fault condition will be generated only once when
pressing on the
Negotiate
button. The default setting is
No Error
. Choices
are:
For electrical port:
No Error
and
Auto-Negotiation Error
.
For 1000Mbps optical port:
No Error
,
Off-line
,
Link Failure
, and
Auto-Negotiation Error
.
Enable Local Capabilities
Allows enabling the local port capabilities by checking all supported
predefined speed, duplex and flow control combination. This setting is
disabled by default.
Note:
The available port capabilities are based on the physical port selected for
the test, which is either electrical or optical.
Local Capabilities
When the local capabilities is enabled, select the supported port
capabilities. Local capabilities are disabled by default. Choices are:
10Base-T, Half Duplex
10Base-T, Full Duplex
100Base-TX, Half Duplex
100Base-TX, Full Duplex
1000Base-T, Full Duplex
1000Base-X, Full Duplex
Symmetric Pause
Asymmetric Pause