Traffic Analyzer Tabs
Ethernet and Fibre Channel Application
189
Capture
Trigger Position
: Allows the selection of the triggered frame position
within the buffer.
Post-Trigger
: The trigger frame is located at the beginning of the
buffer meaning that the buffer will contain the triggered frame with
the following frames.
Mid-Trigger
: The trigger frame is located at the middle of the
buffer meaning that the buffer will contain the triggered frame with
the preceding and following frames.
Pre-Trigger
: The trigger frame is located at the end of the buffer
meaning that the buffer will contain the triggered frame with the
preceding frames.
Status and Controls
Capture Status
: Indicates the status of the data capture:
“--”
: The capture is not started and has not run yet.
Armed...
: The capture is started but waiting for the trigger event.
Capturing...
: The capture is in progress. For
Post-Trigger
and
Mid-Trigger
mode, the trigger event has been captured and the
buffer is filling up.
Completed
: The capture is completed.
Frame Count
: Indicates the number of frames captured that matches
the selected filter criteria. However, for
Mid-trigger
and
Pre-Trigger
,
the frame counter will only be available when the capture is
completed.
Triggered Error
: When trigger on error is selected, it indicates the
error that activated the trigger.
Triggered Frame - Details
: Gives details on the triggered frame. Refer
to
on page 510 for more information.