Traffic Analyzer Tabs
190
IQS-8500 Series and IQS-8120NGE/8130NGE
Capture
Capture
button: Allows to start/stop the data capture. The test must be
Global Test Status and Controls
on page 44) in order
to start capturing and recording data into the buffer. The
Capture
button is not available when the trigger on field match is selected while
its trigger parameters are not valid.
No data will be recorded in the buffer if no frame matches the filter and
the trigger criteria during the data capture.
The data capture stops automatically once the buffer is full. The
maximum buffer capacity is 65 KBytes for IQS-8510B and 256 MBytes
for IQS-8510G, IQS-8525, IQS-8535, IQS-8120NGE, and IQS-8130NGE.
When the capture stops or is manually stopped, the following message
is displayed:
Capture completed. Press Export to save captured
data (the test must be stopped)
. To avoid losing the captured data,
the data must be exported and saved into a file before restarting the
test or creating a new test.
Export
button: Allows to export the data capture into a .pcap file
format and to view the file using
Wireshark
. Refer to
on page 511 for more information.