Pattern Tabs
Ethernet and Fibre Channel Application
255
Pattern TX
Invert
: The generated test pattern will be inverted if the
Invert
check
box is selected meaning that every 0 will be changed for 1 and every 1
for 0. For example, the pattern 1100 will be sent as 0011. The
Invert
check box is cleared by default.
Coupled
: Coupled allows coupling both the TX and RX signal with the
same pattern configuration. This setting is enabled by default.
User Pattern
User Pattern is available when
User Pattern
is selected as the test
pattern.
Pattern #
: Up to 10 patterns can be programmed. Select the pattern
number to configure. The default setting is
1
.
Value
: Enter the pattern value (4 bytes). The default setting is
00 00 00 00
.
Binary
: Allows displaying the pattern value either in binary (when the
Binary
check box is selected) or hexadecimal (when the
Binary
check box is cleared). The
Binary
check box is cleared by default.
Note:
The User Pattern for TX and RX tabs share the same pattern list.
Alarm Generation
Type
: The only available type of pattern alarm is
Pattern Loss
.
On/Off
button: Press the On/Off button to enable/disable the pattern alarm
generation. This setting is disabled (Off) by default.