Expert Mode Tabs
440
IQS-8500 Series and IQS-8120NGE/8130NGE
Ethernet (BERT)
Errors
Enter the threshold value for each error.
Status
: Indicates the real-time pass/fail condition.
Grey LED
: Indicates that
Expert Mode
is disabled or the test did not
run yet.
Green LED
: Indicates that the threshold is respected (
Pass
).
Red LED
: Indicates that the threshold is not respected (
Fail
).
Unit
: Select the unit. Choices are
Second
,
Count
, and
Rate
. The default
setting is
Second
.
Error
Second
Count
Rate
Default
Block
(10Gbps)
0
to
1800
seconds
0
to
18000000000000 1.0E-20
to
1.0E-00
0
second
FCS Error
(Framed Layer 2)
0
to
1800
seconds
0
to
27000000000
4.0E-11
to
1.0E-00
0
second
Symbol
(10/100/1000Mps)
0
to
1800
seconds
0
to
2250000000000 1.0E-14
to
1.0E-00
0
second
Idle
(10/100/1000Mps)
0
to
1800
seconds
0
to
2250000000000 1.0E-14
to
1.0E-00
0
second