Specifications
Ethernet and Fibre Channel Application
459
Fibre Channel Interfaces
For IQS-8120NGE/IQS-8130NGE and IQS-8525/IQS-8535:
Wavelength (nm)
850
1310
1310
1550
Tx level (dBm)
–9 to –2.5
–8.4 to –3
0 to +5
+1 to +5
Rx level sensitivity (dBm)
–15 at FC-4
–18 at FC-4
–18 at FC-4
–16.5 at FC-4
–18 at FC-2
–21 at FC-2
–21 at FC-2
–20.5 at FC-2
–20 at FC-1
–22 at FC-1
–22 at FC-1
–22 at FC-1
Maximum reach
500 m on 50/125 μm MMF
a
4 km
30 km
40 km
300 m on 62.5/125 μm MMF
a
Transmission bit rate (Gbit/s)
1.06/2.125/4.25
1.06/2.125/4.25
1.06/2.125/4.25
1.06/2.125/4.25
Reception bit rate (Gbit/s)
1.06/2.125/4.25
1.06/2.125/4.25
1.06/2.125/4.25
1.06/2.125/4.25
Tx operational wavelength range (nm)
830 to 860
1260 to 1350
1285 to 1345
1544.5 to 1557.5
Measurement accuracy:
Frequency (ppm)
±4.6
±4.6
±4.6
±4.6
Optical power (dB)
±2
±2
±2
±2
Max Rx before damage (dBm)
+3
+3
+3
+3
Jitter compliance
ANSI FC-PI-2
ANSI FC-PI-2
ANSI FC-PI-2
ANSI FC-PI-2
FC classification
ANSI FC-PI-2
ANSI FC-PI-2
ANSI FC-PI-2
ANSI FC-PI-2
Laser type
VCSEL
Fabry-Perot
DFB
DFB
Eye safety
Class 1
Class 1
Class 1
Class 1
Connector
LC
LC
LC
LC
Transceiver type
SFP
SFP
SFP
SFP
F
C
-1
0
X
Wavelength (nm)
850
1310
1310
1550
1550
Tx level (dBm)
–5 to –1
+0.5 max
–6 to –1
–1 to +2
0 to +4
Rx level sensitivity (dBm)
–11.1
–12.6
–14.4
–16
–23
Maximum reach
300 m on 50/125 μm MMF
10 km
10 km
40 km
80 km
30 m on 62.5/125 μm MMF
Transmission bit rate (Gbit/s)
10.5
10.5
10.5
10.5
10.5
Reception bit rate (Gbit/s)
10.5
10.5
10.5
10.5
10.5
Tx operational wavelength range (nm)
840 to 860
1260 to 1355
1290 to 1330
1530 to 1565
1530 to 1565
Measurement accuracy:
Frequency (ppm)
±4.6
±4.6
±4.6
±4.6
±4.6
Optical power (dB)
±2
±2
±2
±2
±2
Max Rx before damage (dBm)
+6
+6
+6
+2
+4
Jitter compliance
ANSI FC-PI-3
ANSI FC-PI-3
ANSI FC-PI-3
ANSI FC-PI-3
ANSI FC-PI-3
FC classification
ANSI FC-PI-3
ANSI FC-PI-3
ANSI FC-PI-3
ANSI FC-PI-3
ANSI FC-PI-3
Laser type
VCSEL
DFB
DFB
EML
EML
Eye safety
Class 1
Class 1
Class 1
Class 1
Class 1
Connector
LC
LC
LC
LC
LC
Transceiver type
XFP
XFP
XFP
XFP
XFP
F
C
-1X
/2
X
/4
X
N
O
T
E
a. Values in the table correspond to FC-1 rate. For FC-2, maximum reach is 300 m on 50/125 μm MMF and 150 m on 62.5/125 μm MMF. For FC-4, maximum reach is 150 m
on 50/125 μm MMF and 70 m on 62.5/125 μm MMF.