Creating and Starting a Test Case
84
IQS-8500 Series and IQS-8120NGE/8130NGE
Ethernet EtherSAM (Y.1564) and RFC 2544 Dual Test Set Test Cases
4.
Framing configuration.
4a.
Set the
Auto-Negotiation
,
Speed
,
Duplex
, and
Flow
Control
parameters. Not
available with Ethernet
10G. Refer to
page 142 for more
information.
4b.
Set the
VLAN
parameters
when required. Refer to
on page 220 for more information.
4c.
Select the
Frame Format
. Choices are
Ethernet II
and
802.3
SNAP
. Refer to
on page 150 for more information.
4d.
Set the
IP Version
(IPv4 or IPv6).
IP Version
is only available
when the IPv6 software option (SK-IPV6) is enabled.
4e.
For IPv4, select the
Automatic IP Address
check box to
dynamically obtain an IP address from a DHCP (Dynamic Host
Configuration Protocol) server or set the source and destination IP
addresses,
Subnet Mask
, and the
Default Gateway
. Refer to
on page 485 for more information.
4f.
For IPv6, press the
IPv6 Config
button to set the IPv6 settings.
on page 487 for more
information.
4g.
Press
Finish
to complete the test setup on this remote module.
The
RFC 2544
’s
Global
tab is automatically displayed.
When the test is created as remote on a unit or on a compatible unit
(IQS-8510B, IQS-8510G, IQS-8525/IQS-8535,
IQS-8120NGE/IQS-8130NGE, or RTU-310/RTU-310G), the SUI is limited
to the following: Test Setup, Tools, System, and About tabs; favorites,
save, load, and report functionality. No test configuration and results
are available.