Running DSL/IP Tests and Viewing Results
104
MAX-630G
DSL Parameter Details
DSL Parameter Details
The
DSL Param Details
tab displays the
Downstream
and
Upstream
parameter results configured in the DSL/IP tests.
When the
Test Interface
for
Auto Test
or
Manual Test
is set to ADSL2+ or
VDSL2 bonding mode, there will be 2 pages of results, one for each DSL
line-pair.
To access the second-pair results, press the
Pair 1
/
2
function key at the
bottom-right of the screen.
Line Status
displays the status of the line under
test during negotiation with the DSLAM. The value
changes from Idle /Activate /Handshake /Training
/Show Time for DSL mode.
Note:
When loading firmware into the Broadcom chipset,
the
Line Status
value displays
Loading M:SS
, where
M:SS is a count down timer.
Operation Mode
is the DSL mode of operation as
negotiated between the unit and the DSLAM.
CO Vendor ID/Version
is a unique 4-digit
alphanumeric identifier of the DSL chipset manufacturer, used on the
CO (central office) side, and its version number.
CO Version
is the version number of the unique alphanumeric
identifier of the DSL chipset used on the CO side.
Sync loss count
is the number of times the unit lost synchronization.
Power Save State
refers to the power-save mode of the DPU
(distribution point unit) and displays one of three states:
L0
(power full
on),
L1
(low power), or
L2
(idle).