Setting Up DSL/IP Tests
G.fast/VDSL2/ADSL2+ Multi-play Test Set
67
Test Setup
Ping Test Setup
The
Test Setup
tab is available only if
Access Mode
is
not
Sync Only
.
Address Format
is
URL
,
IP Address
, or
Gateway
.
When
IPv6 (DHCP)
is set as the
Access Mode
in
Connection Setup
,
IP Address
is changed to
IPv6 Address
.
URL
/
IP Address
lists either the URL or IP Address
where the unit pings.
IPv6 Address
parameter replaces the
URL/IP
Address
when
IPv6 (DHCP)
is set as the
Access
Mode
.
Packet Size
is a value from 32 through 1200 of the number of bytes sent
in one packet. The default value is 32.
Total Pings
is the total number of Ping packets to send out from
1 through 99. The default value is 3.
Timeout
is the time in seconds from 1 through 10, that the unit will wait
for a response back from the destination device.
To configure test setup values:
1.
Press the up/down arrow keys to select the desired parameter.
2.
Press the left/right arrow keys to view and select the options.
OR
3.
Press
on a value to open a list box of options or the alphanumeric
editor screen and use the navigation keys to scroll through.
4.
Press
to confirm the value.
5.
If you make any changes to the parameter values, press the on-screen
function keys to save or cancel your input.