Setting Up Copper Tests
Copper and G.fast/VDSL2/ADSL2+ Multi-play Test Set
91
Test Lead Compensation
Test Lead Compensation
Test Lead Compensation
should be performed when
copper test accuracy is in question, since test lead
characteristics have some impact on copper test
results (mainly resistance, capacitance, and TDR
tests). Test lead characteristics vary with respect to
cable temperature. Refer to
page 8 on how to connect the leads before starting
compensation.
The
Test Lead Compensation
routine also performs
resistance and capacitance compensation. The page
displays the
Pass
/
Fail
status of the last compensation
done.
Note:
Always perform a test lead compensation if the test leads have recently
been removed or replaced.
Date and Time
identifies when the last compensation was done or
application installation time.
Start Compensation
button allows you to start the
Test Lead
Compensation
by overwriting the current test lead characteristics.
To perform a test lead compensation:
1.
Connect the cables to the unit, leave all test leads open, and press
to start compensation.
2.
Follow the on-screen dialogue boxes for next steps.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......