Multimeter Tests
Copper and G.fast/VDSL2/ADSL2+ Multi-play Test Set
115
Voltage
Voltage
The
Voltage
test detects AC RMS and DC voltages in the line and allows you
to measure AC/DC voltages and
Frequency
on A/B/E or T/R/G depending
on the selected
Standard
in
Setup
/
Application Settings
.
Voltage
tests are
not meant, nor is the test set rated, to measure electrical power circuits.
Continuous DC Page
With voltage measurements, you can detect crossed battery, other foreign
unwanted voltages, and even see intermittent breaks or contact if the
voltages fluctuate. Most plant operators allow 3 or 4 volts of DC and/or AC
signal on working loops, although for higher speed broadband circuits
(ADSL2+ or VDSL2), even a few volts indicate a small fault and some
imbalance which may affect the data rate. You would need to run balance
tests such as
Stressed Balance
,
VF/AC Balance
, and/or short the far end
and run
Resistive Balance
to isolate small faults.
Larger foreign/unwanted voltages are a real problem because they indicate
a contact fault and add unwanted noise affecting other signals (including
affecting test set signals). 48 to 52 volts would indicate working POTS. If
you have not already done so, press
and select
Pair Detective
to
identify metallic faults or even wetness.
The
Voltage
test defaults to the
Continuous DC
page
from the
Multimeter
menu. This function measures
each pair, displaying and updating results in
real time
,
until you stop the test. The last valid results then
remain displayed. If the DC value is fluctuating, it
could indicate the presence of moisture in a fault or
possibly a moving or
swinging
metallic fault, causing
intermittent breaks in the DC (such as POTS battery).
To view all lead combinations right away:
Press the
Snapshot
function key.
Continuous AC
and
Continuous DC
are run
synchronously. Press Start/Stop on the keypad to run the test.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......