Multimeter Tests
Copper and G.fast/VDSL2/ADSL2+ Multi-play Test Set
129
Resistance
Continuous
The
Continuous
function measures each pair,
displaying and updating results in
real time
, until you
stop the test. The last valid results then remain
displayed. In
Continuous
mode, significant changes
or fluctuations in the values can indicate wet faults or
intermittent metallic faults (
swinging
faults), or other
foreign voltages on the pair. (Sometimes ground
signals can influence a pair through a ground fault.)
Current Group
is the current test group name, for
example
Multimeter
.
Current Test
displays the test being measured.
When FED is
Enabled
, the FED icon and numeric state are displayed
beside the
Current Test
.
Here you can switch to another test from the given list. However, this
action will terminate the ongoing measurement test.
Selected Pair
allows you to select
All Pairs
or a single wire pair for
measurement.
Cable Parameters
:
Cable Type
displays the ID, Cable Name and Fill, and allows you to
select an entry (with its associated parameters) from the current
Cable Book, to use for testing. The selection is not saved when
leaving the test. The current Cable Book entry is shown by default.
Cable Temperature
is the temperature in either
°F
or
°C
of the
cable under test.
Resistance
displays the resistance per length value of the selected
Cable Type
. The value is updated when
Cable Temperature
/
Type
change.
Threshold Settings
button opens a new page that allows you to set the
resistance thresholds for each pair.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......