Frequency Tests
Copper and G.fast/VDSL2/ADSL2+ Multi-play Test Set
223
WB Attenuation
The
Measured Attn
displays the measured attenuation for the
frequency set in the
Threshold Settings
, and is shown in black.
The pass/fail criteria is calculated by comparing
Measured Attn
to
the equivalent attenuation value displayed in the
Calculated Attn
,
plus half of the
Threshold Tolerance
.
When Mask is enabled for the selected bandwidth:
The end of tolerance or fail point is displayed as a red cursor value.
Good
is the good balance threshold mask for the currently
selected bandwidth, represented by green in the graph.
Test Status
displays the current state of measurement or an error
message.
To select the parameter values:
1.
Press the up/down arrow keys to highlight the desired parameter.
2.
Press the left/right arrow keys to view and select the options.
OR
3.
Press
on a value to open a list box of options or the alphanumeric
editor screen and use the navigation keys to scroll through.
4.
Press
to confirm the value.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......